Skip to main content
Grant Estimator

Revent RVLH150 Exhaust Fan Specifications

ENERGY STAR PD #4661974 · Bathroom/Utility Room · Qualified 2026-05-27
Verified Specification Summary

In EPA dataset 8dv7-nngq, Revent RVLH150 tests at 150 CFM free discharge (152.1 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 12.1 CFM/W efficacy, meeting residential IRC M1505 sizing up to 152 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVLH150 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 152.1 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
12.1 CFM/W (#78/1,145)
Static Retention
101.4% @ 0.25"
Motor Draw
12.4 W (4.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVLH150 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 152.1 CFM out of 150 CFM (101.4% retention, 13.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Revent's 40-unit lineup, RVLH150 (series: ReVent) carries PD #4661974 dating to 2026-05-27. Lighting kit: Yes. At 12.1 CFM/W (#78 of 1,145, top 6.9% of 1,145 rated models, more efficient than 93.1% of rated models, 7.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.4 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 108.6 kWh/yr (~$17.38/yr) continuously. Closest competing matches include ACIQ AEPD150SC (150.0 CFM) and Revent RVL150 (150.0 CFM).

Does Revent RVLH150 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Revent RVLH150 at 0.8 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

Why avoid unvented attic termination with Revent RVLH150?

Under ASHRAE 62.2 best practice, Revent RVLH150 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Revent RVLH150?

Before cutting ceiling drywall or sizing attic transitions for Revent RVLH150, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVLH150 / ReVent PD ID 4661974 (Qualified 2026-05-27)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (152.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Revent RVLH150?

Bathroom ventilation sizing below maps Revent RVLH150 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Revent RVLH150
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 152 sq ft1 CFM/sq ft @ 152.1 CFM
Tall Bath (9-ft Ceiling)Up to 135 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 102 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.5 kWh/yr (~$0.72/yr)12.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2108.6 kWh/yr (~$17.38/yr)12.4 W x 8,760 hrs / 1,000

What peer models sit nearest Revent RVLH150 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Revent RVLH150.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ AEPD150SC 150 / 130.3 CFM 0.9 sones (+0.10) 11.4 CFM/W 6 in. diameter
Revent RVL150 150 / 152.1 CFM 0.8 sones (Same) 12.1 CFM/W 6 in. diameter
Revent RVS150 150 / 155.8 CFM 0.7 sones (-0.10) 12.0 CFM/W 6 in. diameter
Revent RVSH150 150 / 155.8 CFM 0.7 sones (-0.10) 12.0 CFM/W 6 in. diameter
Delta 150LED-ADJ 150 / 155 CFM 0.5 sones (-0.30) 8.8 CFM/W 6 in. diameter

What percentage of room demand does Revent RVLH150 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Revent RVLH150 tested delivery.

Where should contractors skip Revent RVLH150 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Revent RVLH150 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 152.1 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around 0.8 sones up to 152 sq ft
  • Works well for: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Revent RVLH150?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Revent RVLH150.

What duct and room conditions disqualify Revent RVLH150?

Rule out Revent RVLH150 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Revent RVLH150 capacity?

Because static drag at 0.25 in. w.g. lowers Revent RVLH150 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Revent RVLH150 compared with a standard 3.0 sone builder fan?

Tested at 0.8 sones, Revent RVLH150 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Revent RVLH150 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Revent RVLH150 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Revent RVLH150 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVLH150's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVLH150?

Revent RVLH150 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVLH150's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVLH150's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Revent RVLH150 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Revent RVLH150 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories