In EPA dataset 8dv7-nngq, Revent RVLH150 tests at 150 CFM free discharge (152.1 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 12.1 CFM/W efficacy, meeting residential IRC M1505 sizing up to 152 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVLH150 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 152.1 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 12.1 CFM/W (#78/1,145)
- Static Retention
- 101.4% @ 0.25"
- Motor Draw
- 12.4 W (4.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Revent RVLH150 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 152.1 CFM out of 150 CFM (101.4% retention, 13.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Inside Revent's 40-unit lineup, RVLH150 (series: ReVent) carries PD #4661974 dating to 2026-05-27. Lighting kit: Yes. At 12.1 CFM/W (#78 of 1,145, top 6.9% of 1,145 rated models, more efficient than 93.1% of rated models, 7.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.4 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 108.6 kWh/yr (~$17.38/yr) continuously. Closest competing matches include ACIQ AEPD150SC (150.0 CFM) and Revent RVL150 (150.0 CFM).
Does Revent RVLH150 fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Revent RVLH150 at 0.8 sones.
Why avoid unvented attic termination with Revent RVLH150?
Under ASHRAE 62.2 best practice, Revent RVLH150 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Revent RVLH150?
Before cutting ceiling drywall or sizing attic transitions for Revent RVLH150, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Revent (40 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RVLH150 / ReVent | PD ID 4661974 (Qualified 2026-05-27) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (152.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Revent RVLH150?
Bathroom ventilation sizing below maps Revent RVLH150 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 152 sq ft | 1 CFM/sq ft @ 152.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 135 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 102 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 108.6 kWh/yr (~$17.38/yr) | 12.4 W x 8,760 hrs / 1,000 |
What peer models sit nearest Revent RVLH150 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Revent RVLH150.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AEPD150SC | 150 / 130.3 CFM | 0.9 sones (+0.10) | 11.4 CFM/W | 6 in. diameter |
| Revent RVL150 | 150 / 152.1 CFM | 0.8 sones (Same) | 12.1 CFM/W | 6 in. diameter |
| Revent RVS150 | 150 / 155.8 CFM | 0.7 sones (-0.10) | 12.0 CFM/W | 6 in. diameter |
| Revent RVSH150 | 150 / 155.8 CFM | 0.7 sones (-0.10) | 12.0 CFM/W | 6 in. diameter |
| Delta 150LED-ADJ | 150 / 155 CFM | 0.5 sones (-0.30) | 8.8 CFM/W | 6 in. diameter |
What percentage of room demand does Revent RVLH150 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Revent RVLH150 tested delivery.
Where should contractors skip Revent RVLH150 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Revent RVLH150 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 152.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around 0.8 sones up to 152 sq ft
- Works well for: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Revent RVLH150?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Revent RVLH150.
What duct and room conditions disqualify Revent RVLH150?
Rule out Revent RVLH150 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Revent RVLH150 capacity?
Because static drag at 0.25 in. w.g. lowers Revent RVLH150 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Revent RVLH150 compared with a standard 3.0 sone builder fan?
Tested at 0.8 sones, Revent RVLH150 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Revent RVLH150 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Revent RVLH150 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Revent RVLH150 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVLH150's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Revent RVLH150?
Revent RVLH150 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Revent RVLH150's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVLH150's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Revent RVLH150 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Revent RVLH150 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)