AUPU B6-13 Exhaust Fan Specifications

ENERGY STAR PD #4688994 · Bathroom/Utility Room · Qualified 2026-08-05
Verified Specification Summary

Certified by EPA ENERGY STAR, AUPU B6-13 delivers 130 CFM free-air (113.6 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 113 sq ft (8-ft height) or 100 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B6-13 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / 113.6 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
87.4% @ 0.25"
Motor Draw
33.3 W (12.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AUPU B6-13 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 113.6 CFM out of 130 CFM (87.4% retention, 0.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places B6-13 (series: VF6) (PD #4688994) among 35 AUPU entries qualified through 2026-08-05. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Milano TY-130-E (130.0 CFM) and Ortech OD-1209PB (120.0 CFM).

How noisy is AUPU B6-13 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while AUPU B6-13 measures 0.8 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

Why does rigid 4 in. diameter ducting protect AUPU B6-13 airflow?

Connecting AUPU B6-13 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify AUPU B6-13 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for AUPU B6-13 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AUPU (35 models) ENERGY STAR Certified Partner
Model Number & Series B6-13 / VF6 PD ID 4688994 (Qualified 2026-08-05)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (113.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit AUPU B6-13?

Calculated coverage metrics translate AUPU B6-13 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for AUPU B6-13
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 113 sq ft1 CFM/sq ft @ 113.6 CFM
Tall Bath (9-ft Ceiling)Up to 100 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 63 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)12.2 kWh/yr (~$1.95/yr)33.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2291.7 kWh/yr (~$46.67/yr)33.3 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to AUPU B6-13?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Milano TY-130-E 130 / 106.3 CFM 0.7 sones (-0.10) 4.1 CFM/W 6 in. diameter
Ortech OD-1209PB 120 / 101.6 CFM 0.9 sones (+0.10) 4.3 CFM/W 6 in. diameter
Dayton 3DPE5B 130 / N/A CFM 0.7 sones (-0.10) 5.8 CFM/W 6 x 8 in. rectangular
Hampton Bay 7136-02 140 / 124.4 CFM 1.0 sones (+0.20) 3.9 CFM/W 6 in. diameter
HomeWerks Worldwide 7136-02HW 140 / 124.4 CFM 1.0 sones (+0.20) 3.9 CFM/W 6 in. diameter

Does AUPU B6-13 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check AUPU B6-13 percentage capacity without sending data.

Who should not install AUPU B6-13 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting AUPU B6-13 for residential use.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 63 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 113.6 CFM net static output
  • Primary match: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for AUPU B6-13?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around AUPU B6-13.

When is AUPU B6-13 undersized or poorly matched for a bath renovation?

Skip AUPU B6-13 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check AUPU B6-13 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, AUPU B6-13 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does AUPU B6-13 sound output compare to noisy contractor-grade fans?

Rated at 0.8 sones, AUPU B6-13 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define AUPU B6-13?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can AUPU B6-13 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B6-13's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AUPU B6-13?

AUPU B6-13 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AUPU B6-13's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B6-13's safe coverage footprint from 50 sq ft to 44 sq ft.

Does AUPU B6-13 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), AUPU B6-13 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)