Certified by EPA ENERGY STAR, AUPU B6-13S delivers 130 CFM free-air (113.6 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 113 sq ft (8-ft height) or 100 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B6-13S Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 113.6 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 87.4% @ 0.25"
- Motor Draw
- 33.3 W (12.2 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU B6-13S vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 113.6 CFM out of 130 CFM (87.4% retention, 0.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
AUPU maintains 35 active ENERGY STAR blowers; B6-13S (series: VF6) (PD #4688974) gained qualification on 2026-08-05. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Milano TY-130-E (130.0 CFM) and Ortech OD-1209PB (120.0 CFM).
How noisy is AUPU B6-13S compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while AUPU B6-13S measures 0.8 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect AUPU B6-13S airflow?
Connecting AUPU B6-13S through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify AUPU B6-13S performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for AUPU B6-13S lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | B6-13S / VF6 | PD ID 4688974 (Qualified 2026-08-05) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (113.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit AUPU B6-13S?
Calculated coverage metrics translate AUPU B6-13S airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 113 sq ft | 1 CFM/sq ft @ 113.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 100 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 63 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to AUPU B6-13S?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Milano TY-130-E | 130 / 106.3 CFM | 0.7 sones (-0.10) | 4.1 CFM/W | 6 in. diameter |
| Ortech OD-1209PB | 120 / 101.6 CFM | 0.9 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |
| Dayton 3DPE5B | 130 / N/A CFM | 0.7 sones (-0.10) | 5.8 CFM/W | 6 x 8 in. rectangular |
| Hampton Bay 7136-02 | 140 / 124.4 CFM | 1.0 sones (+0.20) | 3.9 CFM/W | 6 in. diameter |
| HomeWerks Worldwide 7136-02HW | 140 / 124.4 CFM | 1.0 sones (+0.20) | 3.9 CFM/W | 6 in. diameter |
Does AUPU B6-13S match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check AUPU B6-13S percentage capacity without sending data.
Does AUPU B6-13S suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying AUPU B6-13S for your remodel.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 63 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Moisture load fits 113.6 CFM net static output
- Best application: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for AUPU B6-13S?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around AUPU B6-13S.
What acoustic sone tier does AUPU B6-13S occupy in EPA filings?
With 0.8 sones at 0.1 in. w.g., AUPU B6-13S operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does AUPU B6-13S add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, AUPU B6-13S averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can AUPU B6-13S pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B6-13S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU B6-13S?
AUPU B6-13S features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU B6-13S's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B6-13S's safe coverage footprint from 50 sq ft to 44 sq ft.
Does AUPU B6-13S pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), AUPU B6-13S easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install AUPU B6-13S in a bathroom remodel?
Avoid specifying AUPU B6-13S in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut AUPU B6-13S airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, AUPU B6-13S achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)