Certified by EPA ENERGY STAR, AUPU B6-11L1 delivers 110 CFM free-air (95.8 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 3.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 95 sq ft (8-ft height) or 85 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B6-11L1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 95.8 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 3.8 CFM/W (#951/1,145)
- Static Retention
- 87.1% @ 0.25"
- Motor Draw
- 28.9 W (10.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU B6-11L1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.8 CFM out of 110 CFM (87.1% retention, 0.6 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places B6-11L1 (series: BF6-11L) (PD #4708514) among 35 AUPU entries qualified through 2026-09-23. Lighting kit: Yes. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.9 watts, about 10.5 kWh/yr (~$1.68/yr at $0.16/kWh) for 1 hr/day shower timers or 253.2 kWh/yr (~$40.51/yr) continuously. Closest competing matches include Tech Drive TD-BF-07 (110.0 CFM) and Broan RB110L1 (110.0 CFM).
How noisy is AUPU B6-11L1 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while AUPU B6-11L1 measures 0.8 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect AUPU B6-11L1 airflow?
Connecting AUPU B6-11L1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify AUPU B6-11L1 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for AUPU B6-11L1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | B6-11L1 / BF6-11L | PD ID 4708514 (Qualified 2026-09-23) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (95.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit AUPU B6-11L1?
Calculated coverage metrics translate AUPU B6-11L1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 95 sq ft | 1 CFM/sq ft @ 95.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 85 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 45 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.5 kWh/yr (~$1.68/yr) | 28.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 253.2 kWh/yr (~$40.51/yr) | 28.9 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to AUPU B6-11L1?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-07 | 110 / 100.2 CFM | 0.8 sones (Same) | 3.8 CFM/W | 6 in. diameter |
| Broan RB110L1 | 110 / 95.7 CFM | 0.8 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| ACIQ AEP110 | 110 / 94.2 CFM | 0.9 sones (+0.10) | 4.2 CFM/W | 6 in. diameter |
| Canarm CEP110 | 110 / 94.2 CFM | 0.9 sones (+0.10) | 4.2 CFM/W | 6 in. diameter |
| Cyclone ESCBP110 | 110 / 101.6 CFM | 0.9 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |
Does AUPU B6-11L1 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check AUPU B6-11L1 percentage capacity without sending data.
What plumbing or duct constraints rule out AUPU B6-11L1?
Compare where AUPU B6-11L1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 45 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 95.8 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for AUPU B6-11L1?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around AUPU B6-11L1.
Is AUPU B6-11L1 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can AUPU B6-11L1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B6-11L1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU B6-11L1?
AUPU B6-11L1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU B6-11L1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B6-11L1's safe coverage footprint from 50 sq ft to 44 sq ft.
Can AUPU B6-11L1 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: AUPU B6-11L1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap AUPU B6-11L1 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, AUPU B6-11L1 lacks adequate reserve.
How does AUPU B6-11L1 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., AUPU B6-11L1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is AUPU B6-11L1 quiet enough for a primary bedroom bathroom?
At 0.8 sones, AUPU B6-11L1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)