In EPA dataset 8dv7-nngq, AUPU BF6-11 tests at 110 CFM free discharge (99.9 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 3.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 99 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU BF6-11 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 99.9 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 90.8% @ 0.25"
- Motor Draw
- 28.2 W (10.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU BF6-11 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99.9 CFM out of 110 CFM (90.8% retention, 3.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside AUPU's 35-unit lineup, BF6-11 (series: BF6-11) carries PD #4573319 dating to 2026-03-11. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.2 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.0 kWh/yr (~$39.52/yr) continuously. Closest competing matches include Tech Drive TD-BF-07 (110.0 CFM) and Broan RB110L1 (110.0 CFM).
Does AUPU BF6-11 fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with AUPU BF6-11 at 0.8 sones.
Why avoid unvented attic termination with AUPU BF6-11?
Under ASHRAE 62.2 best practice, AUPU BF6-11 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern AUPU BF6-11?
Before cutting ceiling drywall or sizing attic transitions for AUPU BF6-11, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BF6-11 / BF6-11 | PD ID 4573319 (Qualified 2026-03-11) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (99.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit AUPU BF6-11?
Bathroom ventilation sizing below maps AUPU BF6-11 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 99 sq ft | 1 CFM/sq ft @ 99.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 49 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.3 kWh/yr (~$1.65/yr) | 28.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 247.0 kWh/yr (~$39.52/yr) | 28.2 W x 8,760 hrs / 1,000 |
What peer models sit nearest AUPU BF6-11 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to AUPU BF6-11.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-07 | 110 / 100.2 CFM | 0.8 sones (Same) | 3.8 CFM/W | 6 in. diameter |
| Broan RB110L1 | 110 / 95.7 CFM | 0.8 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| ACIQ AEP110 | 110 / 94.2 CFM | 0.9 sones (+0.10) | 4.2 CFM/W | 6 in. diameter |
| Canarm CEP110 | 110 / 94.2 CFM | 0.9 sones (+0.10) | 4.2 CFM/W | 6 in. diameter |
| Cyclone ESCBP110 | 110 / 101.6 CFM | 0.9 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |
What percentage of room demand does AUPU BF6-11 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against AUPU BF6-11 tested delivery.
What plumbing or duct constraints rule out AUPU BF6-11?
Compare where AUPU BF6-11 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 99.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around 0.8 sones up to 99 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for AUPU BF6-11?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing AUPU BF6-11.
Can AUPU BF6-11 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: AUPU BF6-11 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap AUPU BF6-11 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, AUPU BF6-11 lacks adequate reserve.
How does AUPU BF6-11 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., AUPU BF6-11 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is AUPU BF6-11 quiet enough for a primary bedroom bathroom?
At 0.8 sones, AUPU BF6-11 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is AUPU BF6-11 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can AUPU BF6-11 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU BF6-11's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU BF6-11?
AUPU BF6-11 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU BF6-11's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU BF6-11's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)