Certified by EPA ENERGY STAR, Tech Drive TD-BF-07 delivers 110 CFM free-air (100.2 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 3.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 100 sq ft (8-ft height) or 89 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-07 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 100.2 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 3.8 CFM/W (#951/1,145)
- Static Retention
- 91.1% @ 0.25"
- Motor Draw
- 28.9 W (10.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Tech Drive TD-BF-07 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.2 CFM out of 110 CFM (91.1% retention, 3.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Tech Drive registers 27 certified models, with SKU TD-BF-07 (series: TD) (PD #2556375) certified since 2023-06-23. Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.9 watts, about 10.5 kWh/yr (~$1.68/yr at $0.16/kWh) for 1 hr/day shower timers or 253.2 kWh/yr (~$40.51/yr) continuously. Closest competing matches include AUPU B6-11L1 (110.0 CFM) and AUPU BF6-11L (110.0 CFM).
How noisy is Tech Drive TD-BF-07 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Tech Drive TD-BF-07 measures 0.8 sones across the 1,145-model registry.
Why does rigid 6 in. diameter ducting protect Tech Drive TD-BF-07 airflow?
Connecting Tech Drive TD-BF-07 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Tech Drive TD-BF-07 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Tech Drive TD-BF-07 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-BF-07 / TD | PD ID 2556375 (Qualified 2023-06-23) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (100.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Tech Drive TD-BF-07?
Calculated coverage metrics translate Tech Drive TD-BF-07 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 89 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.5 kWh/yr (~$1.68/yr) | 28.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 253.2 kWh/yr (~$40.51/yr) | 28.9 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Tech Drive TD-BF-07?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| AUPU B6-11L1 | 110 / 95.8 CFM | 0.8 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| AUPU BF6-11L | 110 / 95.8 CFM | 0.8 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| AUPU B6-11F | 110 / 99.9 CFM | 0.8 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| AUPU BF6-11 | 110 / 99.9 CFM | 0.8 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Broan RB110L1 | 110 / 95.7 CFM | 0.8 sones (Same) | 3.6 CFM/W | 4 in. diameter |
Does Tech Drive TD-BF-07 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Tech Drive TD-BF-07 percentage capacity without sending data.
When does Tech Drive TD-BF-07 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Tech Drive TD-BF-07.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 50 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 100.2 CFM net static output
- Target scenario: Collar pairs with 6 in. diameter duct straight outdoors
Which homeowner questions come up most for Tech Drive TD-BF-07?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Tech Drive TD-BF-07.
Does running Tech Drive TD-BF-07 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Tech Drive TD-BF-07 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Tech Drive TD-BF-07 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-07's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive TD-BF-07?
Tech Drive TD-BF-07 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive TD-BF-07's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-07's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Tech Drive TD-BF-07 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-07 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Tech Drive TD-BF-07?
Do not force Tech Drive TD-BF-07 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Tech Drive TD-BF-07 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Tech Drive TD-BF-07 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.
Will Tech Drive TD-BF-07 disturb adjacent bedrooms during night use?
Acoustic measurement places Tech Drive TD-BF-07 at 0.8 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)