Homeowners specifying AUPU B4-10F gain 100 CFM at 0.1 in. w.g. (81.9 CFM at 0.25 in. w.g.) where it registers #194 of 607 in quietness (0.8 sones) and delivers 4.0 CFM/W efficacy, venting bathrooms up to 81 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B4-10F Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 81.9 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 81.9% @ 0.25"
- Motor Draw
- 25.0 W (9.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU B4-10F vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 100 CFM open-air to 81.9 CFM at 0.25 in. w.g. (81.9% retention, 5.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places B4-10F (series: Flush) (PD #4726034) among 35 AUPU entries qualified through 2026-11-04. Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include ACIQ ANP100 (100.0 CFM) and Canarm CNP100 (100.0 CFM).
What acoustic percentile does AUPU B4-10F occupy among 1,145 bath blowers?
Inspect how AUPU B4-10F positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits AUPU B4-10F best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around AUPU B4-10F housings.
Where do AUPU B4-10F acoustic and static metrics stand?
Compare AUPU B4-10F published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | B4-10F / Flush | PD ID 4726034 (Qualified 2026-11-04) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (81.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can AUPU B4-10F handle taller ceilings or walk-in tub steam?
Evaluate how AUPU B4-10F scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 81 sq ft | 1 CFM/sq ft @ 81.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 72 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 31 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near AUPU B4-10F?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ ANP100 | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Canarm CNP100 | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Cyclone CBP100 | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Cyclone CTP100 | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Kaze Appliance SNP100 | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
Is AUPU B4-10F sized right for your shower or tub room?
Check whether AUPU B4-10F clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Who should not install AUPU B4-10F in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting AUPU B4-10F for residential use.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 31 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 81.9 CFM net static output
- Primary match: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for AUPU B4-10F?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to AUPU B4-10F.
Does AUPU B4-10F satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), AUPU B4-10F clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is AUPU B4-10F undersized or poorly matched for a bath renovation?
Skip AUPU B4-10F if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check AUPU B4-10F CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, AUPU B4-10F registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does AUPU B4-10F sound output compare to noisy contractor-grade fans?
Rated at 0.8 sones, AUPU B4-10F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define AUPU B4-10F?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can AUPU B4-10F pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B4-10F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU B4-10F?
AUPU B4-10F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU B4-10F's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B4-10F's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)