AUPU B4-10F Exhaust Fan Specifications

ENERGY STAR PD #4726034 · Bathroom/Utility Room · Qualified 2026-11-04
Verified Specification Summary

Homeowners specifying AUPU B4-10F gain 100 CFM at 0.1 in. w.g. (81.9 CFM at 0.25 in. w.g.) where it registers #194 of 607 in quietness (0.8 sones) and delivers 4.0 CFM/W efficacy, venting bathrooms up to 81 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B4-10F Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 81.9 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
4.0 CFM/W (#847/1,145)
Static Retention
81.9% @ 0.25"
Motor Draw
25.0 W (9.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AUPU B4-10F vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 81.9 CFM at 0.25 in. w.g. (81.9% retention, 5.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places B4-10F (series: Flush) (PD #4726034) among 35 AUPU entries qualified through 2026-11-04. Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include ACIQ ANP100 (100.0 CFM) and Canarm CNP100 (100.0 CFM).

What acoustic percentile does AUPU B4-10F occupy among 1,145 bath blowers?

Inspect how AUPU B4-10F positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

Which exterior damper path suits AUPU B4-10F best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around AUPU B4-10F housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do AUPU B4-10F acoustic and static metrics stand?

Compare AUPU B4-10F published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AUPU (35 models) ENERGY STAR Certified Partner
Model Number & Series B4-10F / Flush PD ID 4726034 (Qualified 2026-11-04)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (81.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can AUPU B4-10F handle taller ceilings or walk-in tub steam?

Evaluate how AUPU B4-10F scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for AUPU B4-10F
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 81 sq ft1 CFM/sq ft @ 81.9 CFM
Tall Bath (9-ft Ceiling)Up to 72 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 31 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.1 kWh/yr (~$1.46/yr)25.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2219.0 kWh/yr (~$35.04/yr)25.0 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near AUPU B4-10F?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ ANP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Canarm CNP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Cyclone CBP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Cyclone CTP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Kaze Appliance SNP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter

Is AUPU B4-10F sized right for your shower or tub room?

Check whether AUPU B4-10F clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Who should not install AUPU B4-10F in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting AUPU B4-10F for residential use.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 31 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 81.9 CFM net static output
  • Primary match: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for AUPU B4-10F?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to AUPU B4-10F.

Does AUPU B4-10F satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), AUPU B4-10F clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is AUPU B4-10F undersized or poorly matched for a bath renovation?

Skip AUPU B4-10F if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check AUPU B4-10F CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, AUPU B4-10F registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does AUPU B4-10F sound output compare to noisy contractor-grade fans?

Rated at 0.8 sones, AUPU B4-10F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define AUPU B4-10F?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can AUPU B4-10F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B4-10F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AUPU B4-10F?

AUPU B4-10F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AUPU B4-10F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B4-10F's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)