Skip to main content
Grant Estimator

Milano TY-130-E Exhaust Fan Specifications

ENERGY STAR PD #2369813 · Bathroom/Utility Room · Qualified 2020-11-20
Verified Specification Summary

Certified by EPA ENERGY STAR, Milano TY-130-E delivers 130 CFM free-air (106.3 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 4.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 106 sq ft (8-ft height) or 94 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Milano TY-130-E Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / 106.3 CFM
Noise @ 0.1"
0.7 sones (#135/607)
Efficacy Rank
4.1 CFM/W (#821/1,145)
Static Retention
81.8% @ 0.25"
Motor Draw
31.7 W (11.6 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Milano TY-130-E vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 130 CFM open-air to 106.3 CFM at 0.25 in. w.g. (81.8% retention, 5.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places TY-130-E (series: Easy installation) (PD #2369813) among 6 Milano entries qualified through 2020-11-20. Lighting kit: No. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 31.7 watts, about 11.6 kWh/yr (~$1.86/yr at $0.16/kWh) for 1 hr/day shower timers or 277.7 kWh/yr (~$44.43/yr) continuously. Closest competing matches include AUPU B6-13 (130.0 CFM) and AUPU B6-13S (130.0 CFM).

How noisy is Milano TY-130-E compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Milano TY-130-E measures 0.7 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.7 sone: 0.7 sones (32nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.7 sone: 0.7 sones (P32)

Why does rigid 6 in. diameter ducting protect Milano TY-130-E airflow?

Connecting Milano TY-130-E through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Milano TY-130-E performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Milano TY-130-E lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Milano (6 models) ENERGY STAR Certified Partner
Model Number & Series TY-130-E / Easy installation PD ID 2369813 (Qualified 2020-11-20)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (106.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.7 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Milano TY-130-E?

Calculated coverage metrics translate Milano TY-130-E airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Milano TY-130-E
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 106 sq ft1 CFM/sq ft @ 106.3 CFM
Tall Bath (9-ft Ceiling)Up to 94 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 56 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)11.6 kWh/yr (~$1.86/yr)31.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2277.7 kWh/yr (~$44.43/yr)31.7 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Milano TY-130-E?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
AUPU B6-13 130 / 113.6 CFM 0.8 sones (+0.10) 3.9 CFM/W 4 in. diameter
AUPU B6-13S 130 / 113.6 CFM 0.8 sones (+0.10) 3.9 CFM/W 4 in. diameter
AUPU B6-13L 130 / 110.2 CFM 0.8 sones (+0.10) 3.8 CFM/W 4 in. diameter
Dayton 3DPE5B 130 / N/A CFM 0.7 sones (Same) 5.8 CFM/W 6 x 8 in. rectangular
Ortech OD-1209PB 120 / 101.6 CFM 0.9 sones (+0.20) 4.3 CFM/W 6 in. diameter

Does Milano TY-130-E match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Milano TY-130-E percentage capacity without sending data.

When does Milano TY-130-E fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Milano TY-130-E.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 56 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Moisture load fits 106.3 CFM net static output
  • Target scenario: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Milano TY-130-E?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Milano TY-130-E.

How much airflow does Milano TY-130-E retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Milano TY-130-E produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Will Milano TY-130-E disturb adjacent bedrooms during night use?

Acoustic measurement places Milano TY-130-E at 0.7 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Does running Milano TY-130-E continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Milano TY-130-E draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Milano TY-130-E pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Milano TY-130-E's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Milano TY-130-E?

Milano TY-130-E features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Milano TY-130-E's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Milano TY-130-E's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Milano TY-130-E code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Milano TY-130-E clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Milano TY-130-E?

Do not force Milano TY-130-E into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories