In EPA dataset 8dv7-nngq, AUPU AV11AL1 tests at 110 CFM free discharge (89 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 4.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 89 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU AV11AL1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 89 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 4.4 CFM/W (#679/1,145)
- Static Retention
- 80.9% @ 0.25"
- Motor Draw
- 25.0 W (9.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU AV11AL1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 89 CFM at 0.25 in. w.g. (80.9% retention, 6.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places AV11AL1 (series: AV) (PD #2338642) among 35 AUPU entries qualified through 2019-05-17. Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include AERO PURE ABF110L5W (110.0 CFM) and Tech Drive TD-BF-07 (110.0 CFM).
Does AUPU AV11AL1 fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with AUPU AV11AL1 at 0.7 sones.
Why avoid unvented attic termination with AUPU AV11AL1?
Under ASHRAE 62.2 best practice, AUPU AV11AL1 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern AUPU AV11AL1?
Before cutting ceiling drywall or sizing attic transitions for AUPU AV11AL1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AV11AL1 / AV | PD ID 2338642 (Qualified 2019-05-17) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (89 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit AUPU AV11AL1?
Bathroom ventilation sizing below maps AUPU AV11AL1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 89 sq ft | 1 CFM/sq ft @ 89 CFM |
| Tall Bath (9-ft Ceiling) | Up to 79 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 39 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |
What peer models sit nearest AUPU AV11AL1 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to AUPU AV11AL1.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| AERO PURE ABF110L5W | 110 / 89 CFM | 0.7 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-07 | 110 / 100.2 CFM | 0.8 sones (+0.10) | 3.8 CFM/W | 6 in. diameter |
| Broan RB110L1 | 110 / 95.7 CFM | 0.8 sones (+0.10) | 3.6 CFM/W | 4 in. diameter |
| Greenheck SP-A125 | 109 / N/A CFM | 0.7 sones (Same) | 5.8 CFM/W | 6 x 8 in. rectangular |
| ACIQ ANP100 | 100 / 97.3 CFM | 0.8 sones (+0.10) | 4.7 CFM/W | 4 in. diameter |
What percentage of room demand does AUPU AV11AL1 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against AUPU AV11AL1 tested delivery.
Who should not install AUPU AV11AL1 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting AUPU AV11AL1 for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 89 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around 0.7 sones up to 89 sq ft
- Primary match: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for AUPU AV11AL1?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing AUPU AV11AL1.
Does AUPU AV11AL1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), AUPU AV11AL1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is AUPU AV11AL1 undersized or poorly matched for a bath renovation?
Skip AUPU AV11AL1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check AUPU AV11AL1 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, AUPU AV11AL1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does AUPU AV11AL1 sound output compare to noisy contractor-grade fans?
Rated at 0.7 sones, AUPU AV11AL1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define AUPU AV11AL1?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can AUPU AV11AL1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU AV11AL1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU AV11AL1?
AUPU AV11AL1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU AV11AL1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU AV11AL1's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)