AUPU B6-13L Exhaust Fan Specifications

ENERGY STAR PD #4688954 · Bathroom/Utility Room · Qualified 2026-08-05
Verified Specification Summary

In EPA dataset 8dv7-nngq, AUPU B6-13L tests at 130 CFM free discharge (110.2 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 3.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 110 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B6-13L Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / 110.2 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
3.8 CFM/W (#951/1,145)
Static Retention
84.8% @ 0.25"
Motor Draw
34.2 W (12.5 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AUPU B6-13L vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 130 CFM open-air to 110.2 CFM at 0.25 in. w.g. (84.8% retention, 2.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4688954 verifies B6-13L (series: VF6) under AUPU (35 listed models, qualified 2026-08-05). Lighting kit: Yes. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 34.2 watts, about 12.5 kWh/yr (~$2.00/yr at $0.16/kWh) for 1 hr/day shower timers or 299.6 kWh/yr (~$47.94/yr) continuously. Closest competing matches include Milano TY-130-E (130.0 CFM) and Ortech OD-1209PB (120.0 CFM).

Does AUPU B6-13L fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with AUPU B6-13L at 0.8 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

Why avoid unvented attic termination with AUPU B6-13L?

Under ASHRAE 62.2 best practice, AUPU B6-13L needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern AUPU B6-13L?

Before cutting ceiling drywall or sizing attic transitions for AUPU B6-13L, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AUPU (35 models) ENERGY STAR Certified Partner
Model Number & Series B6-13L / VF6 PD ID 4688954 (Qualified 2026-08-05)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (110.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit AUPU B6-13L?

Bathroom ventilation sizing below maps AUPU B6-13L motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for AUPU B6-13L
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 110 sq ft1 CFM/sq ft @ 110.2 CFM
Tall Bath (9-ft Ceiling)Up to 97 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 60 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)12.5 kWh/yr (~$2.00/yr)34.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2299.6 kWh/yr (~$47.94/yr)34.2 W x 8,760 hrs / 1,000

What peer models sit nearest AUPU B6-13L in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to AUPU B6-13L.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Milano TY-130-E 130 / 106.3 CFM 0.7 sones (-0.10) 4.1 CFM/W 6 in. diameter
Ortech OD-1209PB 120 / 101.6 CFM 0.9 sones (+0.10) 4.3 CFM/W 6 in. diameter
Hampton Bay 7136-02 140 / 124.4 CFM 1.0 sones (+0.20) 3.9 CFM/W 6 in. diameter
HomeWerks Worldwide 7136-02HW 140 / 124.4 CFM 1.0 sones (+0.20) 3.9 CFM/W 6 in. diameter
Dayton 3DPE5B 130 / N/A CFM 0.7 sones (-0.10) 5.8 CFM/W 6 x 8 in. rectangular

What percentage of room demand does AUPU B6-13L cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against AUPU B6-13L tested delivery.

Which bath layouts should avoid specifying AUPU B6-13L?

Match AUPU B6-13L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 110.2 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around 0.8 sones up to 110 sq ft
  • Optimal use: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for AUPU B6-13L?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing AUPU B6-13L.

Where does AUPU B6-13L sit on acoustic comfort for senior homeowners?

Measuring 0.8 sones, AUPU B6-13L operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does AUPU B6-13L cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running AUPU B6-13L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can AUPU B6-13L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B6-13L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AUPU B6-13L?

AUPU B6-13L features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AUPU B6-13L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B6-13L's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can AUPU B6-13L ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), AUPU B6-13L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does AUPU B6-13L run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with AUPU B6-13L.

What happens to AUPU B6-13L CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, AUPU B6-13L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)