S&P PC110XP Exhaust Fan Specifications

ENERGY STAR PD #2402469 · Bathroom/Utility Room · Qualified 2022-09-16
Verified Specification Summary

In EPA dataset 8dv7-nngq, S&P PC110XP tests at 100 CFM free discharge (83.8 CFM at 0.25 in. w.g.) and registers #239 of 607 in quietness (0.9 sones) and delivers 3.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 83 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PC110XP Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 83.8 CFM
Noise @ 0.1"
0.9 sones (#239/607)
Efficacy Rank
3.6 CFM/W (#1,017/1,145)
Static Retention
83.8% @ 0.25"
Motor Draw
27.8 W (10.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P PC110XP vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 83.8 CFM at 0.25 in. w.g. (83.8% retention, 3.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: S&P registers 29 certified models, with SKU PC110XP (series: PC) (PD #2402469) certified since 2022-09-16. Lighting kit: No. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.8 watts, about 10.1 kWh/yr (~$1.62/yr at $0.16/kWh) for 1 hr/day shower timers or 243.5 kWh/yr (~$38.96/yr) continuously. Closest competing matches include VOTATEC VO-FN4W26-AC-100 (100.0 CFM) and Wintek BPT15B-100H1 (100.0 CFM).

Does S&P PC110XP fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with S&P PC110XP at 0.9 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.9 sone: 0.9 sones (43rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.9 sone: 0.9 sones (P43)

Why avoid unvented attic termination with S&P PC110XP?

Under ASHRAE 62.2 best practice, S&P PC110XP needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern S&P PC110XP?

Before cutting ceiling drywall or sizing attic transitions for S&P PC110XP, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series PC110XP / PC PD ID 2402469 (Qualified 2022-09-16)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (83.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.9 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit S&P PC110XP?

Bathroom ventilation sizing below maps S&P PC110XP motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for S&P PC110XP
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 83 sq ft1 CFM/sq ft @ 83.8 CFM
Tall Bath (9-ft Ceiling)Up to 74 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 33 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.1 kWh/yr (~$1.62/yr)27.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2243.5 kWh/yr (~$38.96/yr)27.8 W x 8,760 hrs / 1,000

What peer models sit nearest S&P PC110XP in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to S&P PC110XP.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
VOTATEC VO-FN4W26-AC-100 100 / 85 CFM 0.9 sones (Same) 3.9 CFM/W 4 in. diameter
Wintek BPT15B-100H1 100 / 85 CFM 0.9 sones (Same) 3.9 CFM/W 4 in. diameter
Nektra 33003853 100 / 84.1 CFM 0.9 sones (Same) 4.1 CFM/W 4 in. diameter
Nektra Pro 33003856 100 / 84.1 CFM 0.9 sones (Same) 4.1 CFM/W 4 in. diameter
Wintek BPT15B-100H2 100 / 84.1 CFM 0.9 sones (Same) 4.1 CFM/W 4 in. diameter

What percentage of room demand does S&P PC110XP cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against S&P PC110XP tested delivery.

Who should not install S&P PC110XP in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting S&P PC110XP for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 83.8 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 0.9 sones up to 83 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for S&P PC110XP?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing S&P PC110XP.

What electrical efficiency and runtime kWh define S&P PC110XP?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can S&P PC110XP pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PC110XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P PC110XP?

S&P PC110XP features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P PC110XP's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PC110XP's safe coverage footprint from 50 sq ft to 44 sq ft.

Does S&P PC110XP satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), S&P PC110XP clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is S&P PC110XP undersized or poorly matched for a bath renovation?

Skip S&P PC110XP if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check S&P PC110XP CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, S&P PC110XP registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does S&P PC110XP sound output compare to noisy contractor-grade fans?

Rated at 0.9 sones, S&P PC110XP operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories