Certified by EPA ENERGY STAR, S&P PC80XP delivers 90 CFM free-air (70.9 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 4.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 70 sq ft (8-ft height) or 63 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PC80XP Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 70.9 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 78.8% @ 0.25"
- Motor Draw
- 21.4 W (7.8 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does S&P PC80XP vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 90 CFM open-air to 70.9 CFM at 0.25 in. w.g. (78.8% retention, 8.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
S&P maintains 29 active ENERGY STAR blowers; PC80XP (series: PC) (PD #3626825) gained qualification on 2024-08-30. Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.4 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 187.5 kWh/yr (~$30.00/yr) continuously. Closest competing matches include Ortech OD-9005PB (90.0 CFM) and Dayton 5AE68B (90.0 CFM).
How noisy is S&P PC80XP compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while S&P PC80XP measures 0.7 sones across the 1,145-model registry.
Why does rigid 6 in. diameter ducting protect S&P PC80XP airflow?
Connecting S&P PC80XP through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify S&P PC80XP performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for S&P PC80XP lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PC80XP / PC | PD ID 3626825 (Qualified 2024-08-30) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (70.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit S&P PC80XP?
Calculated coverage metrics translate S&P PC80XP airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 70 sq ft | 1 CFM/sq ft @ 70.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 20 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.8 kWh/yr (~$1.25/yr) | 21.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 187.5 kWh/yr (~$30.00/yr) | 21.4 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to S&P PC80XP?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Ortech OD-9005PB | 90 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Dayton 5AE68B | 90 / N/A CFM | 0.8 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |
| Greenheck SP-B90 | 90 / 72 CFM | 0.8 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-11-plus | 90 / 79.5 CFM | 0.8 sones (+0.10) | 4.4 CFM/W | 4 in. diameter |
| Air King AK90LS6 | 90 / 72.7 CFM | 0.8 sones (+0.10) | 4.5 CFM/W | 6 in. diameter |
Does S&P PC80XP match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check S&P PC80XP percentage capacity without sending data.
Where should contractors skip S&P PC80XP on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for S&P PC80XP carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 20 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 70.9 CFM net static output
- Works well for: Collar pairs with 6 in. diameter duct straight outdoors
Which homeowner questions come up most for S&P PC80XP?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around S&P PC80XP.
How loud is S&P PC80XP compared with a standard 3.0 sone builder fan?
Tested at 0.7 sones, S&P PC80XP operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does S&P PC80XP consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, S&P PC80XP draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can S&P PC80XP pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PC80XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P PC80XP?
S&P PC80XP features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P PC80XP's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PC80XP's safe coverage footprint from 50 sq ft to 44 sq ft.
How does S&P PC80XP score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), S&P PC80XP delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify S&P PC80XP?
Rule out S&P PC80XP when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke S&P PC80XP capacity?
Because static drag at 0.25 in. w.g. lowers S&P PC80XP from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)