Skip to main content
Grant Estimator

Dayton 5AE68B Exhaust Fan Specifications

ENERGY STAR PD #2335082 · Bathroom/Utility Room · Qualified 2015-10-15
Verified Specification Summary

Certified by EPA ENERGY STAR, Dayton 5AE68B delivers 90 CFM free-air (unpublished 0.25 in. w.g. output) and registers #194 of 607 in quietness (0.8 sones) and delivers 4.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 90 sq ft (8-ft height) or 80 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Dayton 5AE68B Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / N/A CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
0.1" test only
Motor Draw
20.9 W (7.6 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Dayton 5AE68B vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Free-discharge delivery reaches 90 CFM (#789 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Dayton's 12-unit lineup, 5AE68B (series: 5AE68B) carries PD #2335082 dating to 2015-10-15. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.9 watts, about 7.6 kWh/yr (~$1.22/yr at $0.16/kWh) for 1 hr/day shower timers or 183.1 kWh/yr (~$29.30/yr) continuously. Closest competing matches include Greenheck SP-B90 (90.0 CFM) and Tech Drive TD-BF-11-plus (90.0 CFM).

How noisy is Dayton 5AE68B compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Dayton 5AE68B measures 0.8 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

Why does rigid 6 in. diameter ducting protect Dayton 5AE68B airflow?

Connecting Dayton 5AE68B through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Dayton 5AE68B performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Dayton 5AE68B lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Dayton (12 models) ENERGY STAR Certified Partner
Model Number & Series 5AE68B / 5AE68B PD ID 2335082 (Qualified 2015-10-15)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (90 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Dayton 5AE68B?

Calculated coverage metrics translate Dayton 5AE68B airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Dayton 5AE68B
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 90 sq ft1 CFM/sq ft @ 90 CFM
Tall Bath (9-ft Ceiling)Up to 80 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 40 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.6 kWh/yr (~$1.22/yr)20.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2183.1 kWh/yr (~$29.30/yr)20.9 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Dayton 5AE68B?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Greenheck SP-B90 90 / 72 CFM 0.8 sones (Same) 4.3 CFM/W 6 in. diameter
Tech Drive TD-BF-11-plus 90 / 79.5 CFM 0.8 sones (Same) 4.4 CFM/W 4 in. diameter
Air King AK90LS6 90 / 72.7 CFM 0.8 sones (Same) 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-02 90 / 71.5 CFM 0.8 sones (Same) 3.9 CFM/W 4 in. diameter
Ortech ODC-9008 90 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter

Does Dayton 5AE68B match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Dayton 5AE68B percentage capacity without sending data.

Who should not install Dayton 5AE68B in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Dayton 5AE68B for residential use.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 40 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 90 CFM net static output
  • Primary match: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Dayton 5AE68B?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Dayton 5AE68B.

Why check Dayton 5AE68B CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Dayton 5AE68B registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

How does Dayton 5AE68B sound output compare to noisy contractor-grade fans?

Rated at 0.8 sones, Dayton 5AE68B operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Dayton 5AE68B?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Dayton 5AE68B pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Dayton 5AE68B's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Dayton 5AE68B?

Dayton 5AE68B features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Dayton 5AE68B's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Dayton 5AE68B's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Dayton 5AE68B satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Dayton 5AE68B clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Dayton 5AE68B undersized or poorly matched for a bath renovation?

Skip Dayton 5AE68B if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories