Homeowners specifying Tech Drive TD-BF-11-plus gain 90 CFM at 0.1 in. w.g. (79.5 CFM at 0.25 in. w.g.) where it registers #194 of 607 in quietness (0.8 sones) and delivers 4.4 CFM/W efficacy, venting bathrooms up to 79 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-11-plus Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 79.5 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 4.4 CFM/W (#679/1,145)
- Static Retention
- 88.3% @ 0.25"
- Motor Draw
- 20.5 W (7.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Tech Drive TD-BF-11-plus vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 79.5 CFM out of 90 CFM (88.3% retention, 0.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Tech Drive registers 27 certified models, with SKU TD-BF-11-plus (series: TD) (PD #4697514) certified since 2026-09-02. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include Air King AK90LS6 (90.0 CFM) and Dayton 5AE68B (90.0 CFM).
What acoustic percentile does Tech Drive TD-BF-11-plus occupy among 1,145 bath blowers?
Inspect how Tech Drive TD-BF-11-plus positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Tech Drive TD-BF-11-plus best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Tech Drive TD-BF-11-plus housings.
Where do Tech Drive TD-BF-11-plus acoustic and static metrics stand?
Compare Tech Drive TD-BF-11-plus published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-BF-11-plus / TD | PD ID 4697514 (Qualified 2026-09-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (79.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Tech Drive TD-BF-11-plus handle taller ceilings or walk-in tub steam?
Evaluate how Tech Drive TD-BF-11-plus scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 79 sq ft | 1 CFM/sq ft @ 79.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 70 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 29 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 179.6 kWh/yr (~$28.74/yr) | 20.5 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Tech Drive TD-BF-11-plus?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Air King AK90LS6 | 90 / 72.7 CFM | 0.8 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| Dayton 5AE68B | 90 / N/A CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| Greenheck SP-B90 | 90 / 72 CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| Ortech ODC-9008 | 90 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| BV BV-BF-01-PLUS | 90 / 82.9 CFM | 0.8 sones (Same) | 4.8 CFM/W | 4 in. diameter |
Is Tech Drive TD-BF-11-plus sized right for your shower or tub room?
Check whether Tech Drive TD-BF-11-plus clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Does Tech Drive TD-BF-11-plus suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Tech Drive TD-BF-11-plus for your remodel.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 29 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Moisture load fits 79.5 CFM net static output
- Best application: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Tech Drive TD-BF-11-plus?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Tech Drive TD-BF-11-plus.
Who should NOT install Tech Drive TD-BF-11-plus in a bathroom remodel?
Avoid specifying Tech Drive TD-BF-11-plus in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Tech Drive TD-BF-11-plus airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Tech Drive TD-BF-11-plus achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Tech Drive TD-BF-11-plus occupy in EPA filings?
With 0.8 sones at 0.1 in. w.g., Tech Drive TD-BF-11-plus operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does Tech Drive TD-BF-11-plus add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Tech Drive TD-BF-11-plus averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Tech Drive TD-BF-11-plus pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-11-plus's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive TD-BF-11-plus?
Tech Drive TD-BF-11-plus features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive TD-BF-11-plus's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-11-plus's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Tech Drive TD-BF-11-plus pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-11-plus easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)