Rated for 90 CFM open-air (72.7 CFM at 0.25 in. w.g.), Air King AK90LS6 registers #194 of 607 in quietness (0.8 sones) and delivers 4.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 72 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK90LS6 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 72.7 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 80.8% @ 0.25"
- Motor Draw
- 20.0 W (7.3 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Air King AK90LS6 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 90 CFM open-air to 72.7 CFM at 0.25 in. w.g. (80.8% retention, 6.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Air King registers 62 certified models, with SKU AK90LS6 (series: Air King) (PD #2395005) certified since 2022-04-22. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.0 watts, about 7.3 kWh/yr (~$1.17/yr at $0.16/kWh) for 1 hr/day shower timers or 175.2 kWh/yr (~$28.03/yr) continuously. Closest competing matches include Tech Drive TD-BF-11-plus (90.0 CFM) and Dayton 5AE68B (90.0 CFM).
How does Air King AK90LS6 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Air King AK90LS6 (0.8 sones).
How do flex elbows choke Air King AK90LS6 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Air King AK90LS6 moving full rated CFM.
Does Air King AK90LS6 meet residential exhaust fan code specs?
Inspect Air King AK90LS6 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK90LS6 / Air King | PD ID 2395005 (Qualified 2022-04-22) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (72.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Air King AK90LS6 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Air King AK90LS6 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 72 sq ft | 1 CFM/sq ft @ 72.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 64 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 22 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.3 kWh/yr (~$1.17/yr) | 20.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 175.2 kWh/yr (~$28.03/yr) | 20.0 W x 8,760 hrs / 1,000 |
Which competing models share Air King AK90LS6 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-11-plus | 90 / 79.5 CFM | 0.8 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| Dayton 5AE68B | 90 / N/A CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| Greenheck SP-B90 | 90 / 72 CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| Ortech ODC-9008 | 90 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| BV BV-BF-01-PLUS | 90 / 82.9 CFM | 0.8 sones (Same) | 4.8 CFM/W | 4 in. diameter |
How much airflow margin does Air King AK90LS6 give your bath?
Run a quick local room-volume check for Air King AK90LS6 by entering square footage and ceiling height to spot under-vented steam risks early.
When does Air King AK90LS6 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Air King AK90LS6.
Limitations & Who Should Skip
- Steam or walk-in tub room > 22 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 72 sq ft with 8-ft ceilings (64 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Air King AK90LS6?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Air King AK90LS6.
Which bathroom layouts should pick a larger blower than Air King AK90LS6?
Do not force Air King AK90LS6 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Air King AK90LS6 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Air King AK90LS6 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.
Will Air King AK90LS6 disturb adjacent bedrooms during night use?
Acoustic measurement places Air King AK90LS6 at 0.8 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Does running Air King AK90LS6 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Air King AK90LS6 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Air King AK90LS6 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK90LS6's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King AK90LS6?
Air King AK90LS6 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King AK90LS6's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK90LS6's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Air King AK90LS6 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Air King AK90LS6 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)