Skip to main content
Grant Estimator

KORA SBF90N Exhaust Fan Specifications

ENERGY STAR PD #2399642 · Bathroom/Utility Room · Qualified 2022-07-19
Verified Specification Summary

Certified by EPA ENERGY STAR, KORA SBF90N delivers 93.7 CFM free-air (unpublished 0.25 in. w.g. output) and registers #194 of 607 in quietness (0.8 sones) and delivers 3.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 93 sq ft (8-ft height) or 83 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KORA SBF90N Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
93.7 / N/A CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
3.8 CFM/W (#951/1,145)
Static Retention
0.1" test only
Motor Draw
24.7 W (9.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does KORA SBF90N vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Free-discharge delivery reaches 93.7 CFM (#788 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: KORA registers 5 certified models, with SKU SBF90N (series: Ceiling Exhaust Fan) (PD #2399642) certified since 2022-07-19. Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.7 watts, about 9.0 kWh/yr (~$1.44/yr at $0.16/kWh) for 1 hr/day shower timers or 216.4 kWh/yr (~$34.62/yr) continuously. Closest competing matches include Tech Drive TD-BF-02 (90.0 CFM) and Dayton 5AE68B (90.0 CFM).

How noisy is KORA SBF90N compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while KORA SBF90N measures 0.8 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

Why does rigid 4 in. diameter ducting protect KORA SBF90N airflow?

Connecting KORA SBF90N through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify KORA SBF90N performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for KORA SBF90N lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share KORA (5 models) ENERGY STAR Certified Partner
Model Number & Series SBF90N / Ceiling Exhaust Fan PD ID 2399642 (Qualified 2022-07-19)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (93.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit KORA SBF90N?

Calculated coverage metrics translate KORA SBF90N airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for KORA SBF90N
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 93 sq ft1 CFM/sq ft @ 93.7 CFM
Tall Bath (9-ft Ceiling)Up to 83 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 43 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.0 kWh/yr (~$1.44/yr)24.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2216.4 kWh/yr (~$34.62/yr)24.7 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to KORA SBF90N?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Tech Drive TD-BF-02 90 / 71.5 CFM 0.8 sones (Same) 3.9 CFM/W 4 in. diameter
Dayton 5AE68B 90 / N/A CFM 0.8 sones (Same) 4.3 CFM/W 6 in. diameter
Greenheck SP-B90 90 / 72 CFM 0.8 sones (Same) 4.3 CFM/W 6 in. diameter
Tech Drive TD-BF-11-plus 90 / 79.5 CFM 0.8 sones (Same) 4.4 CFM/W 4 in. diameter
AUPU B4-10L1 100 / 79.8 CFM 0.8 sones (Same) 3.9 CFM/W 4 in. diameter

Does KORA SBF90N match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check KORA SBF90N percentage capacity without sending data.

Does KORA SBF90N suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying KORA SBF90N for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 43 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 93.7 CFM net static output
  • Best application: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for KORA SBF90N?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around KORA SBF90N.

Does KORA SBF90N pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), KORA SBF90N easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install KORA SBF90N in a bathroom remodel?

Avoid specifying KORA SBF90N in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut KORA SBF90N airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, KORA SBF90N achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does KORA SBF90N occupy in EPA filings?

With 0.8 sones at 0.1 in. w.g., KORA SBF90N operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does KORA SBF90N add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, KORA SBF90N averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can KORA SBF90N pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KORA SBF90N's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing KORA SBF90N?

KORA SBF90N features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change KORA SBF90N's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KORA SBF90N's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories