Skip to main content
Grant Estimator

BV BV-BF-01-PLUS Exhaust Fan Specifications

ENERGY STAR PD #3994341 · Bathroom/Utility Room · Qualified 2025-01-24
Verified Specification Summary

Tested under HVI protocols, the BV BV-BF-01-PLUS exhaust unit achieves 90 CFM at 0.1 in. w.g. (82.9 CFM at 0.25 in. w.g.), registers #194 of 607 in quietness (0.8 sones) and delivers 4.8 CFM/W efficacy, covering standard baths up to 82 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside BV BV-BF-01-PLUS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / 82.9 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
4.8 CFM/W (#534/1,145)
Static Retention
92.1% @ 0.25"
Motor Draw
18.8 W (6.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does BV BV-BF-01-PLUS vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 82.9 CFM out of 90 CFM (92.1% retention, 4.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside BV's 3-unit lineup, BV-BF-01-PLUS (series: BV-BF-01-PLUS) carries PD #3994341 dating to 2025-01-24. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.8 watts, about 6.9 kWh/yr (~$1.10/yr at $0.16/kWh) for 1 hr/day shower timers or 164.7 kWh/yr (~$26.35/yr) continuously. Closest competing matches include Ortech ODC-9008 (90.0 CFM) and Air King AK90LS6 (90.0 CFM).

Where do BV BV-BF-01-PLUS sones rank across EPA ENERGY STAR fans?

Comparing BV BV-BF-01-PLUS (0.8 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

What attic duct routing preserves BV BV-BF-01-PLUS CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on BV BV-BF-01-PLUS, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does BV BV-BF-01-PLUS measure up on airflow and noise ratings?

Each row below breaks down BV BV-BF-01-PLUS certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share BV (3 models) ENERGY STAR Certified Partner
Model Number & Series BV-BF-01-PLUS / BV-BF-01-PLUS PD ID 3994341 (Qualified 2025-01-24)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (82.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect BV BV-BF-01-PLUS CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for BV BV-BF-01-PLUS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 82 sq ft1 CFM/sq ft @ 82.9 CFM
Tall Bath (9-ft Ceiling)Up to 73 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 32 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.9 kWh/yr (~$1.10/yr)18.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2164.7 kWh/yr (~$26.35/yr)18.8 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against BV BV-BF-01-PLUS?

Compare BV BV-BF-01-PLUS side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Ortech ODC-9008 90 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Air King AK90LS6 90 / 72.7 CFM 0.8 sones (Same) 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-11-plus 90 / 79.5 CFM 0.8 sones (Same) 4.4 CFM/W 4 in. diameter
Dayton 5AE68B 90 / N/A CFM 0.8 sones (Same) 4.3 CFM/W 6 in. diameter
Greenheck SP-B90 90 / 72 CFM 0.8 sones (Same) 4.3 CFM/W 6 in. diameter

Can you size BV BV-BF-01-PLUS for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against BV BV-BF-01-PLUS verified capacity.

What plumbing or duct constraints rule out BV BV-BF-01-PLUS?

Compare where BV BV-BF-01-PLUS excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 82.9 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 0.8 sones up to 82 sq ft
  • Suited to: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to BV BV-BF-01-PLUS?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for BV BV-BF-01-PLUS.

Why might a contractor swap BV BV-BF-01-PLUS for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, BV BV-BF-01-PLUS lacks adequate reserve.

How does BV BV-BF-01-PLUS handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., BV BV-BF-01-PLUS yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is BV BV-BF-01-PLUS quiet enough for a primary bedroom bathroom?

At 0.8 sones, BV BV-BF-01-PLUS operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is BV BV-BF-01-PLUS energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can BV BV-BF-01-PLUS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from BV BV-BF-01-PLUS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing BV BV-BF-01-PLUS?

BV BV-BF-01-PLUS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change BV BV-BF-01-PLUS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing BV BV-BF-01-PLUS's safe coverage footprint from 50 sq ft to 44 sq ft.

Can BV BV-BF-01-PLUS serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: BV BV-BF-01-PLUS supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories