Tested under HVI protocols, the BV BV-BF-01-PLUS exhaust unit achieves 90 CFM at 0.1 in. w.g. (82.9 CFM at 0.25 in. w.g.), registers #194 of 607 in quietness (0.8 sones) and delivers 4.8 CFM/W efficacy, covering standard baths up to 82 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside BV BV-BF-01-PLUS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 82.9 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 4.8 CFM/W (#534/1,145)
- Static Retention
- 92.1% @ 0.25"
- Motor Draw
- 18.8 W (6.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does BV BV-BF-01-PLUS vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 82.9 CFM out of 90 CFM (92.1% retention, 4.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside BV's 3-unit lineup, BV-BF-01-PLUS (series: BV-BF-01-PLUS) carries PD #3994341 dating to 2025-01-24. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.8 watts, about 6.9 kWh/yr (~$1.10/yr at $0.16/kWh) for 1 hr/day shower timers or 164.7 kWh/yr (~$26.35/yr) continuously. Closest competing matches include Ortech ODC-9008 (90.0 CFM) and Air King AK90LS6 (90.0 CFM).
Where do BV BV-BF-01-PLUS sones rank across EPA ENERGY STAR fans?
Comparing BV BV-BF-01-PLUS (0.8 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves BV BV-BF-01-PLUS CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on BV BV-BF-01-PLUS, preventing premature peeling paint and mold growth.
How does BV BV-BF-01-PLUS measure up on airflow and noise ratings?
Each row below breaks down BV BV-BF-01-PLUS certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | BV (3 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BV-BF-01-PLUS / BV-BF-01-PLUS | PD ID 3994341 (Qualified 2025-01-24) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (82.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect BV BV-BF-01-PLUS CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 82 sq ft | 1 CFM/sq ft @ 82.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 73 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 32 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.9 kWh/yr (~$1.10/yr) | 18.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 164.7 kWh/yr (~$26.35/yr) | 18.8 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against BV BV-BF-01-PLUS?
Compare BV BV-BF-01-PLUS side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Ortech ODC-9008 | 90 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Air King AK90LS6 | 90 / 72.7 CFM | 0.8 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-11-plus | 90 / 79.5 CFM | 0.8 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| Dayton 5AE68B | 90 / N/A CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| Greenheck SP-B90 | 90 / 72 CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
Can you size BV BV-BF-01-PLUS for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against BV BV-BF-01-PLUS verified capacity.
What plumbing or duct constraints rule out BV BV-BF-01-PLUS?
Compare where BV BV-BF-01-PLUS excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 82.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around 0.8 sones up to 82 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to BV BV-BF-01-PLUS?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for BV BV-BF-01-PLUS.
Why might a contractor swap BV BV-BF-01-PLUS for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, BV BV-BF-01-PLUS lacks adequate reserve.
How does BV BV-BF-01-PLUS handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., BV BV-BF-01-PLUS yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is BV BV-BF-01-PLUS quiet enough for a primary bedroom bathroom?
At 0.8 sones, BV BV-BF-01-PLUS operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is BV BV-BF-01-PLUS energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can BV BV-BF-01-PLUS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from BV BV-BF-01-PLUS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing BV BV-BF-01-PLUS?
BV BV-BF-01-PLUS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change BV BV-BF-01-PLUS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing BV BV-BF-01-PLUS's safe coverage footprint from 50 sq ft to 44 sq ft.
Can BV BV-BF-01-PLUS serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: BV BV-BF-01-PLUS supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)