Ortech ODC-9008 Exhaust Fan Specifications

ENERGY STAR PD #2398541 · Bathroom/Utility Room · Qualified 2022-06-24
Verified Specification Summary

The Ortech ODC-9008 (OD) moves 90 CFM at 0.1 in. w.g. (97.3 CFM at 0.25 in. w.g.), registers #194 of 607 in quietness (0.8 sones), and delivers 4.7 CFM/W efficacy, sizing bathrooms up to 97 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODC-9008 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / 97.3 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
108.1% @ 0.25"
Motor Draw
19.1 W (7.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech ODC-9008 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97.3 CFM out of 90 CFM (108.1% retention, 20.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Ortech's 27-unit lineup, ODC-9008 (series: OD) carries PD #2398541 dating to 2022-06-24. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 19.1 watts, about 7.0 kWh/yr (~$1.12/yr at $0.16/kWh) for 1 hr/day shower timers or 167.3 kWh/yr (~$26.77/yr) continuously. Closest competing matches include BV BV-BF-01-PLUS (90.0 CFM) and BV BV-BF-05 (90.0 CFM).

Where does Ortech ODC-9008 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.8 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

How does duct geometry alter Ortech ODC-9008 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Ortech ODC-9008?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Ortech ODC-9008 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series ODC-9008 / OD PD ID 2398541 (Qualified 2022-06-24)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (97.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Ortech ODC-9008 ventilate safely?

Sizing outputs below convert Ortech ODC-9008 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Ortech ODC-9008
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 97 sq ft1 CFM/sq ft @ 97.3 CFM
Tall Bath (9-ft Ceiling)Up to 86 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 47 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.0 kWh/yr (~$1.12/yr)19.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2167.3 kWh/yr (~$26.77/yr)19.1 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Ortech ODC-9008 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
BV BV-BF-01-PLUS 90 / 82.9 CFM 0.8 sones (Same) 4.8 CFM/W 4 in. diameter
BV BV-BF-05 90 / 75.4 CFM 0.8 sones (Same) 4.8 CFM/W 4 in. diameter
Air King AK90LS6 90 / 72.7 CFM 0.8 sones (Same) 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-11-plus 90 / 79.5 CFM 0.8 sones (Same) 4.4 CFM/W 4 in. diameter
Dayton 5AE68B 90 / N/A CFM 0.8 sones (Same) 4.3 CFM/W 6 in. diameter

Will Ortech ODC-9008 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Ortech ODC-9008 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Ortech ODC-9008 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Ortech ODC-9008.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 47 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 97 sq ft with 8-ft ceilings (86 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Ortech ODC-9008?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Ortech ODC-9008.

How much airflow does Ortech ODC-9008 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Ortech ODC-9008 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Ortech ODC-9008 disturb adjacent bedrooms during night use?

Acoustic measurement places Ortech ODC-9008 at 0.8 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Does running Ortech ODC-9008 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Ortech ODC-9008 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Ortech ODC-9008 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODC-9008's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech ODC-9008?

Ortech ODC-9008 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech ODC-9008's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODC-9008's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Ortech ODC-9008 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Ortech ODC-9008 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Ortech ODC-9008?

Do not force Ortech ODC-9008 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.