Rated for 50 CFM open-air (41.1 CFM at 0.25 in. w.g.), Air King AK50S registers #83 of 607 in quietness (0.5 sones) and delivers 4.1 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 41 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK50S Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 41.1 CFM
- Noise @ 0.1"
- 0.5 sones (#83/607)
- Efficacy Rank
- 4.1 CFM/W (#821/1,145)
- Static Retention
- 82.2% @ 0.25"
- Motor Draw
- 12.2 W (4.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Air King AK50S vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 41.1 CFM at 0.25 in. w.g. (82.2% retention, 5.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Air King's 62-unit lineup, AK50S (series: Air King) carries PD #2271825 dating to 2016-07-01. Lighting kit: No. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 12.2 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 106.9 kWh/yr (~$17.10/yr) continuously. Closest competing matches include Broan AE50 (50.0 CFM) and Broan AE50=A000HF2WITHAE50F (50.0 CFM).
How does Air King AK50S acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Air King AK50S (0.5 sones).
How do flex elbows choke Air King AK50S at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Air King AK50S moving full rated CFM.
Does Air King AK50S meet residential exhaust fan code specs?
Inspect Air King AK50S mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK50S / Air King | PD ID 2271825 (Qualified 2016-07-01) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (41.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Air King AK50S airflow output?
Annual electricity figures and room square-footage ceilings below reflect Air King AK50S tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 41 sq ft | 1 CFM/sq ft @ 41.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 36 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 106.9 kWh/yr (~$17.10/yr) | 12.2 W x 8,760 hrs / 1,000 |
Which competing models share Air King AK50S airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan AE50 | 50 / 51.9 CFM | 0.5 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| Broan AE50=A000HF2WITHAE50F | 50 / 51.9 CFM | 0.5 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| Broan AE50 = A000HFKTC WITH AE50F1 | 50 / 51.9 CFM | 0.5 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| Broan AE50=A000HFKTwithAE50F1 | 50 / 51.9 CFM | 0.5 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| Broan AE50=A000HFNFwithAE50F1 | 50 / 51.9 CFM | 0.5 sones (Same) | 3.5 CFM/W | 4 in. diameter |
How much airflow margin does Air King AK50S give your bath?
Run a quick local room-volume check for Air King AK50S by entering square footage and ceiling height to spot under-vented steam risks early.
Who should not install Air King AK50S in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Air King AK50S for residential use.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 41 sq ft with 8-ft ceilings (36 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Air King AK50S?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Air King AK50S.
Why check Air King AK50S CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Air King AK50S registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Air King AK50S sound output compare to noisy contractor-grade fans?
Rated at 0.5 sones, Air King AK50S operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Air King AK50S?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Air King AK50S pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK50S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King AK50S?
Air King AK50S features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King AK50S's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK50S's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Air King AK50S satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Air King AK50S clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Air King AK50S undersized or poorly matched for a bath renovation?
Skip Air King AK50S if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)