Certified by EPA ENERGY STAR, Broan AE50 = A000HFKTC WITH AE50F1 delivers 50 CFM free-air (51.9 CFM at 0.25 in. w.g.) and registers #83 of 607 in quietness (0.5 sones) and delivers 3.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 51 sq ft (8-ft height) or 46 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE50 = A000HFKTC WITH AE50F1 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 51.9 CFM
- Noise @ 0.1"
- 0.5 sones (#83/607)
- Efficacy Rank
- 3.5 CFM/W (#1,038/1,145)
- Static Retention
- 103.8% @ 0.25"
- Motor Draw
- 14.3 W (5.2 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan AE50 = A000HFKTC WITH AE50F1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 51.9 CFM out of 50 CFM (103.8% retention, 16.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Broan AE50 = A000HFKTC WITH AE50F1 (series: FLEX SERIES) under PD #3999571 (207 models registered, 2025-03-07). Lighting kit: No. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 14.3 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 125.3 kWh/yr (~$20.05/yr) continuously. Closest competing matches include Air King AK50S (50.0 CFM) and Air King FR50 (50.0 CFM).
How noisy is Broan AE50 = A000HFKTC WITH AE50F1 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Broan AE50 = A000HFKTC WITH AE50F1 measures 0.5 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Broan AE50 = A000HFKTC WITH AE50F1 airflow?
Connecting Broan AE50 = A000HFKTC WITH AE50F1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Broan AE50 = A000HFKTC WITH AE50F1 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan AE50 = A000HFKTC WITH AE50F1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE50 = A000HFKTC WITH AE50F1 / FLEX SERIES | PD ID 3999571 (Qualified 2025-03-07) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (51.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Broan AE50 = A000HFKTC WITH AE50F1?
Calculated coverage metrics translate Broan AE50 = A000HFKTC WITH AE50F1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 51 sq ft | 1 CFM/sq ft @ 51.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 46 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.2 kWh/yr (~$0.83/yr) | 14.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 125.3 kWh/yr (~$20.05/yr) | 14.3 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Broan AE50 = A000HFKTC WITH AE50F1?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Air King AK50S | 50 / 41.1 CFM | 0.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Air King FR50 | 50 / 42 CFM | 0.6 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
| Ortech ODE-5004 | 50 / 43.6 CFM | 0.4 sones (-0.10) | 3.4 CFM/W | 4 in. diameter |
| ACIQ AP50 | 50 / 42.3 CFM | 0.4 sones (-0.10) | 3.3 CFM/W | 4 in. diameter |
| ACIQ ANP50 | 50 / 42.3 CFM | 0.4 sones (-0.10) | 4.0 CFM/W | 4 in. diameter |
Does Broan AE50 = A000HFKTC WITH AE50F1 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan AE50 = A000HFKTC WITH AE50F1 percentage capacity without sending data.
Where should contractors skip Broan AE50 = A000HFKTC WITH AE50F1 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan AE50 = A000HFKTC WITH AE50F1 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 51.9 CFM net static output
- Works well for: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Broan AE50 = A000HFKTC WITH AE50F1?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan AE50 = A000HFKTC WITH AE50F1.
Will long attic ducting choke Broan AE50 = A000HFKTC WITH AE50F1 capacity?
Because static drag at 0.25 in. w.g. lowers Broan AE50 = A000HFKTC WITH AE50F1 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Broan AE50 = A000HFKTC WITH AE50F1 compared with a standard 3.0 sone builder fan?
Tested at 0.5 sones, Broan AE50 = A000HFKTC WITH AE50F1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Broan AE50 = A000HFKTC WITH AE50F1 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Broan AE50 = A000HFKTC WITH AE50F1 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Broan AE50 = A000HFKTC WITH AE50F1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE50 = A000HFKTC WITH AE50F1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE50 = A000HFKTC WITH AE50F1?
Broan AE50 = A000HFKTC WITH AE50F1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE50 = A000HFKTC WITH AE50F1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE50 = A000HFKTC WITH AE50F1's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Broan AE50 = A000HFKTC WITH AE50F1 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan AE50 = A000HFKTC WITH AE50F1 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Broan AE50 = A000HFKTC WITH AE50F1?
Rule out Broan AE50 = A000HFKTC WITH AE50F1 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)