Skip to main content
Grant Estimator

ACIQ AP50 Exhaust Fan Specifications

ENERGY STAR PD #3629724 · Bathroom/Utility Room · Qualified 2024-09-27
Verified Specification Summary

In EPA dataset 8dv7-nngq, ACIQ AP50 tests at 50 CFM free discharge (42.3 CFM at 0.25 in. w.g.) and registers #50 of 607 in quietness (0.4 sones) and delivers 3.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 42 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ AP50 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 42.3 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
3.3 CFM/W (#1,077/1,145)
Static Retention
84.6% @ 0.25"
Motor Draw
15.2 W (5.5 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does ACIQ AP50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 42.3 CFM at 0.25 in. w.g. (84.6% retention, 3.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3629724 verifies AP50 (series: AP) under ACIQ (15 listed models, qualified 2024-09-27). Lighting kit: No. At 3.3 CFM/W (#1,077 of 1,145, below median tier among 1,145 rated models; more efficient than 4.8% of rated models, 1.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 15.2 watts, about 5.5 kWh/yr (~$0.88/yr at $0.16/kWh) for 1 hr/day shower timers or 133.2 kWh/yr (~$21.31/yr) continuously. Closest competing matches include Ortech ODE-5004 (50.0 CFM) and Cyclone CBP50 (50.0 CFM).

Does ACIQ AP50 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with ACIQ AP50 at 0.4 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

Why avoid unvented attic termination with ACIQ AP50?

Under ASHRAE 62.2 best practice, ACIQ AP50 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern ACIQ AP50?

Before cutting ceiling drywall or sizing attic transitions for ACIQ AP50, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share ACIQ (15 models) ENERGY STAR Certified Partner
Model Number & Series AP50 / AP PD ID 3629724 (Qualified 2024-09-27)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (42.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit ACIQ AP50?

Bathroom ventilation sizing below maps ACIQ AP50 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for ACIQ AP50
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 42 sq ft1 CFM/sq ft @ 42.3 CFM
Tall Bath (9-ft Ceiling)Up to 37 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.5 kWh/yr (~$0.88/yr)15.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2133.2 kWh/yr (~$21.31/yr)15.2 W x 8,760 hrs / 1,000

What peer models sit nearest ACIQ AP50 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to ACIQ AP50.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Ortech ODE-5004 50 / 43.6 CFM 0.4 sones (Same) 3.4 CFM/W 4 in. diameter
Cyclone CBP50 50 / 42.3 CFM 0.4 sones (Same) 4.0 CFM/W 4 in. diameter
S&P PC50XP 50 / 42.3 CFM 0.4 sones (Same) 4.0 CFM/W 4 in. diameter
Broan AE50 50 / 51.9 CFM 0.5 sones (+0.10) 3.5 CFM/W 4 in. diameter
Broan AE50=A000HF2WITHAE50F 50 / 51.9 CFM 0.5 sones (+0.10) 3.5 CFM/W 4 in. diameter

What percentage of room demand does ACIQ AP50 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against ACIQ AP50 tested delivery.

When does ACIQ AP50 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering ACIQ AP50.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 42.3 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around 0.4 sones up to 42 sq ft
  • Target scenario: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for ACIQ AP50?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing ACIQ AP50.

How much airflow does ACIQ AP50 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, ACIQ AP50 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will ACIQ AP50 disturb adjacent bedrooms during night use?

Acoustic measurement places ACIQ AP50 at 0.4 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Does running ACIQ AP50 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of ACIQ AP50 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can ACIQ AP50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ AP50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing ACIQ AP50?

ACIQ AP50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change ACIQ AP50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ AP50's safe coverage footprint from 50 sq ft to 44 sq ft.

Is ACIQ AP50 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), ACIQ AP50 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than ACIQ AP50?

Do not force ACIQ AP50 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories