Tested under HVI protocols, the S&P PC50XP exhaust unit achieves 50 CFM at 0.1 in. w.g. (42.3 CFM at 0.25 in. w.g.), registers #50 of 607 in quietness (0.4 sones) and delivers 4.0 CFM/W efficacy, covering standard baths up to 42 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PC50XP Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 42.3 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
4.0 CFM/W (#847/1,145)
Static Retention
84.6% @ 0.25"
Motor Draw
12.5 W (4.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P PC50XP vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 42.3 CFM at 0.25 in. w.g. (84.6% retention, 3.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms S&P PC50XP (series: PC) under PD #2375488 (29 models registered, 2021-03-26). Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 12.5 watts, about 4.6 kWh/yr (~$0.74/yr at $0.16/kWh) for 1 hr/day shower timers or 109.5 kWh/yr (~$17.52/yr) continuously. Closest competing matches include ACIQ ANP50 (50.0 CFM) and Cyclone CBP50 (50.0 CFM).

Where do S&P PC50XP sones rank across EPA ENERGY STAR fans?

Comparing S&P PC50XP (0.4 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

What attic duct routing preserves S&P PC50XP CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on S&P PC50XP, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does S&P PC50XP measure up on airflow and noise ratings?

Each row below breaks down S&P PC50XP certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series PC50XP / PC PD ID 2375488 (Qualified 2021-03-26)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (42.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect S&P PC50XP CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for S&P PC50XP
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 42 sq ft1 CFM/sq ft @ 42.3 CFM
Tall Bath (9-ft Ceiling)Up to 37 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.6 kWh/yr (~$0.74/yr)12.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2109.5 kWh/yr (~$17.52/yr)12.5 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against S&P PC50XP?

Compare S&P PC50XP side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ ANP50 50 / 42.3 CFM 0.4 sones (Same) 4.0 CFM/W 4 in. diameter
Cyclone CBP50 50 / 42.3 CFM 0.4 sones (Same) 4.0 CFM/W 4 in. diameter
Ortech ODE-5004 50 / 43.6 CFM 0.4 sones (Same) 3.4 CFM/W 4 in. diameter
ACIQ AP50 50 / 42.3 CFM 0.4 sones (Same) 3.3 CFM/W 4 in. diameter
Air King AK50S 50 / 41.1 CFM 0.5 sones (+0.10) 4.1 CFM/W 4 in. diameter

Can you size S&P PC50XP for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against S&P PC50XP verified capacity.

Does S&P PC50XP suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying S&P PC50XP for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 42.3 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 0.4 sones up to 42 sq ft
  • Best application: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to S&P PC50XP?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for S&P PC50XP.

What acoustic sone tier does S&P PC50XP occupy in EPA filings?

With 0.4 sones at 0.1 in. w.g., S&P PC50XP operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does S&P PC50XP add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, S&P PC50XP averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can S&P PC50XP pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PC50XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P PC50XP?

S&P PC50XP features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P PC50XP's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PC50XP's safe coverage footprint from 50 sq ft to 44 sq ft.

Does S&P PC50XP pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), S&P PC50XP easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install S&P PC50XP in a bathroom remodel?

Avoid specifying S&P PC50XP in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut S&P PC50XP airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, S&P PC50XP achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories