Rated for 50 CFM open-air (42.3 CFM at 0.25 in. w.g.), ACIQ ANP50 registers #50 of 607 in quietness (0.4 sones) and delivers 4.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 42 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ ANP50 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 42.3 CFM
- Noise @ 0.1"
- 0.4 sones (#50/607)
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 84.6% @ 0.25"
- Motor Draw
- 12.5 W (4.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does ACIQ ANP50 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 42.3 CFM at 0.25 in. w.g. (84.6% retention, 3.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places ANP50 (series: ANP) (PD #3629721) among 15 ACIQ entries qualified through 2024-09-27. Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 12.5 watts, about 4.6 kWh/yr (~$0.74/yr at $0.16/kWh) for 1 hr/day shower timers or 109.5 kWh/yr (~$17.52/yr) continuously. Closest competing matches include Cyclone CBP50 (50.0 CFM) and S&P PC50XP (50.0 CFM).
How does ACIQ ANP50 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against ACIQ ANP50 (0.4 sones).
How do flex elbows choke ACIQ ANP50 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps ACIQ ANP50 moving full rated CFM.
Does ACIQ ANP50 meet residential exhaust fan code specs?
Inspect ACIQ ANP50 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | ACIQ (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ANP50 / ANP | PD ID 3629721 (Qualified 2024-09-27) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (42.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.4 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match ACIQ ANP50 airflow output?
Annual electricity figures and room square-footage ceilings below reflect ACIQ ANP50 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 42 sq ft | 1 CFM/sq ft @ 42.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 37 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.6 kWh/yr (~$0.74/yr) | 12.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 109.5 kWh/yr (~$17.52/yr) | 12.5 W x 8,760 hrs / 1,000 |
Which competing models share ACIQ ANP50 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Cyclone CBP50 | 50 / 42.3 CFM | 0.4 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| S&P PC50XP | 50 / 42.3 CFM | 0.4 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Ortech ODE-5004 | 50 / 43.6 CFM | 0.4 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| Air King AK50S | 50 / 41.1 CFM | 0.5 sones (+0.10) | 4.1 CFM/W | 4 in. diameter |
| Air King LEDAK50 | 50 / 35 CFM | 0.3 sones (-0.10) | 4.4 CFM/W | 4 in. diameter |
How much airflow margin does ACIQ ANP50 give your bath?
Run a quick local room-volume check for ACIQ ANP50 by entering square footage and ceiling height to spot under-vented steam risks early.
When does ACIQ ANP50 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering ACIQ ANP50.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 42 sq ft with 8-ft ceilings (37 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about ACIQ ANP50?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to ACIQ ANP50.
How much airflow does ACIQ ANP50 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, ACIQ ANP50 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will ACIQ ANP50 disturb adjacent bedrooms during night use?
Acoustic measurement places ACIQ ANP50 at 0.4 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Does running ACIQ ANP50 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of ACIQ ANP50 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can ACIQ ANP50 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ ANP50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing ACIQ ANP50?
ACIQ ANP50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change ACIQ ANP50's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ ANP50's safe coverage footprint from 50 sq ft to 44 sq ft.
Is ACIQ ANP50 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), ACIQ ANP50 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than ACIQ ANP50?
Do not force ACIQ ANP50 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)