Skip to main content
Grant Estimator

Greenheck SP-B50 Exhaust Fan Specifications

ENERGY STAR PD #2364769 · Bathroom/Utility Room · Qualified 2020-08-10
Verified Specification Summary

Certified by EPA ENERGY STAR, Greenheck SP-B50 delivers 63 CFM free-air (unpublished 0.25 in. w.g. output) and registers #50 of 607 in quietness (0.4 sones) and delivers 4.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 63 sq ft (8-ft height) or 56 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-B50 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
63 / N/A CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
4.0 CFM/W (#847/1,145)
Static Retention
0.1" test only
Motor Draw
15.8 W (5.8 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck SP-B50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Free-discharge delivery reaches 63 CFM (#1,060 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Greenheck's 31-unit lineup, SP-B50 (series: SP) carries PD #2364769 dating to 2020-08-10. Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 15.8 watts, about 5.8 kWh/yr (~$0.93/yr at $0.16/kWh) for 1 hr/day shower timers or 138.4 kWh/yr (~$22.14/yr) continuously. Closest competing matches include Dayton 3DPE2 (63.0 CFM) and Tech Drive TD-BF-06-plus (60.0 CFM).

How noisy is Greenheck SP-B50 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Greenheck SP-B50 measures 0.4 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

Why does rigid 6 in. diameter ducting protect Greenheck SP-B50 airflow?

Connecting Greenheck SP-B50 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Greenheck SP-B50 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Greenheck SP-B50 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series SP-B50 / SP PD ID 2364769 (Qualified 2020-08-10)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (63 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Greenheck SP-B50?

Calculated coverage metrics translate Greenheck SP-B50 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Greenheck SP-B50
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 63 sq ft1 CFM/sq ft @ 63 CFM
Tall Bath (9-ft Ceiling)Up to 56 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.8 kWh/yr (~$0.93/yr)15.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2138.4 kWh/yr (~$22.14/yr)15.8 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Greenheck SP-B50?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Dayton 3DPE2 63 / N/A CFM 0.4 sones (Same) 4.0 CFM/W 6 in. diameter
Tech Drive TD-BF-06-plus 60 / 51.5 CFM 0.3 sones (-0.10) 3.7 CFM/W 4 in. diameter
Dayton 1UBH6B 70 / N/A CFM 0.5 sones (+0.10) 4.4 CFM/W 6 in. diameter
Tech Drive TD-BF-06 70 / 60.4 CFM 0.3 sones (-0.10) 4.6 CFM/W 4 in. diameter
Win Air BPT14-13E 70 / 60.4 CFM 0.3 sones (-0.10) 4.6 CFM/W 4 in. diameter

Does Greenheck SP-B50 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Greenheck SP-B50 percentage capacity without sending data.

What plumbing or duct constraints rule out Greenheck SP-B50?

Compare where Greenheck SP-B50 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 63 CFM net static output
  • Suited to: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Greenheck SP-B50?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Greenheck SP-B50.

Is Greenheck SP-B50 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Greenheck SP-B50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-B50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck SP-B50?

Greenheck SP-B50 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck SP-B50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-B50's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Greenheck SP-B50 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Greenheck SP-B50 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Greenheck SP-B50 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Greenheck SP-B50 lacks adequate reserve.

How does Greenheck SP-B50 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Greenheck SP-B50 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is Greenheck SP-B50 quiet enough for a primary bedroom bathroom?

At 0.4 sones, Greenheck SP-B50 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories