Skip to main content
Grant Estimator

Tech Drive TD-BF-06-plus Exhaust Fan Specifications

ENERGY STAR PD #4697494 · Bathroom/Utility Room · Qualified 2026-09-02
Verified Specification Summary

Homeowners specifying Tech Drive TD-BF-06-plus gain 60 CFM at 0.1 in. w.g. (51.5 CFM at 0.25 in. w.g.) where it registers #24 of 607 in quietness (0.3 sones) and delivers 3.7 CFM/W efficacy, venting bathrooms up to 51 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-06-plus Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
60 / 51.5 CFM
Noise @ 0.1"
0.3 sones (#24/607)
Efficacy Rank
3.7 CFM/W (#987/1,145)
Static Retention
85.8% @ 0.25"
Motor Draw
16.2 W (5.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Tech Drive TD-BF-06-plus vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 51.5 CFM out of 60 CFM (85.8% retention, 1.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Tech Drive maintains 27 active ENERGY STAR blowers; TD-BF-06-plus (series: TD) (PD #4697494) gained qualification on 2026-09-02. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.2 watts, about 5.9 kWh/yr (~$0.94/yr at $0.16/kWh) for 1 hr/day shower timers or 141.9 kWh/yr (~$22.70/yr) continuously. Closest competing matches include Dayton 3DPE2 (63.0 CFM) and Greenheck SP-B50 (63.0 CFM).

What acoustic percentile does Tech Drive TD-BF-06-plus occupy among 1,145 bath blowers?

Inspect how Tech Drive TD-BF-06-plus positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.3 sone: 0.3 sones (8th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.3 sone: 0.3 sones (P8)

Which exterior damper path suits Tech Drive TD-BF-06-plus best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Tech Drive TD-BF-06-plus housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Tech Drive TD-BF-06-plus acoustic and static metrics stand?

Compare Tech Drive TD-BF-06-plus published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Tech Drive (27 models) ENERGY STAR Certified Partner
Model Number & Series TD-BF-06-plus / TD PD ID 4697494 (Qualified 2026-09-02)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (51.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.3 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Tech Drive TD-BF-06-plus handle taller ceilings or walk-in tub steam?

Evaluate how Tech Drive TD-BF-06-plus scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-06-plus
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 51 sq ft1 CFM/sq ft @ 51.5 CFM
Tall Bath (9-ft Ceiling)Up to 45 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.9 kWh/yr (~$0.94/yr)16.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2141.9 kWh/yr (~$22.70/yr)16.2 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Tech Drive TD-BF-06-plus?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Dayton 3DPE2 63 / N/A CFM 0.4 sones (+0.10) 4.0 CFM/W 6 in. diameter
Greenheck SP-B50 63 / N/A CFM 0.4 sones (+0.10) 4.0 CFM/W 6 in. diameter
Air King LEDAK50 50 / 35 CFM 0.3 sones (Same) 4.4 CFM/W 4 in. diameter
ACIQ ANP50 50 / 42.3 CFM 0.4 sones (+0.10) 4.0 CFM/W 4 in. diameter
Cyclone CBP50 50 / 42.3 CFM 0.4 sones (+0.10) 4.0 CFM/W 4 in. diameter

Is Tech Drive TD-BF-06-plus sized right for your shower or tub room?

Check whether Tech Drive TD-BF-06-plus clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Which bath layouts should avoid specifying Tech Drive TD-BF-06-plus?

Match Tech Drive TD-BF-06-plus directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 51.5 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Tech Drive TD-BF-06-plus?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Tech Drive TD-BF-06-plus.

Where does Tech Drive TD-BF-06-plus sit on acoustic comfort for senior homeowners?

Measuring 0.3 sones, Tech Drive TD-BF-06-plus operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Tech Drive TD-BF-06-plus cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Tech Drive TD-BF-06-plus 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Tech Drive TD-BF-06-plus pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-06-plus's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Tech Drive TD-BF-06-plus?

Tech Drive TD-BF-06-plus features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Tech Drive TD-BF-06-plus's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-06-plus's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Tech Drive TD-BF-06-plus ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-06-plus covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Tech Drive TD-BF-06-plus run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Tech Drive TD-BF-06-plus.

What happens to Tech Drive TD-BF-06-plus CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Tech Drive TD-BF-06-plus moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories