Certified by EPA ENERGY STAR, Air King LEDAK50 delivers 50 CFM free-air (35 CFM at 0.25 in. w.g.) and registers #24 of 607 in quietness (0.3 sones) and delivers 4.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 35 sq ft (8-ft height) or 31 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King LEDAK50 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 35 CFM
- Noise @ 0.1"
- 0.3 sones (#24/607)
- Efficacy Rank
- 4.4 CFM/W (#679/1,145)
- Static Retention
- 70.0% @ 0.25"
- Motor Draw
- 11.4 W (4.2 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Air King LEDAK50 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 35 CFM at 0.25 in. w.g. (70.0% retention, 17.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Air King LEDAK50 (series: Air King) under PD #2280666 (62 models registered, 2016-10-04). Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 11.4 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 99.9 kWh/yr (~$15.98/yr) continuously. Closest competing matches include ACIQ ANP50 (50.0 CFM) and Cyclone CBP50 (50.0 CFM).
How noisy is Air King LEDAK50 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Air King LEDAK50 measures 0.3 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Air King LEDAK50 airflow?
Connecting Air King LEDAK50 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Air King LEDAK50 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Air King LEDAK50 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | LEDAK50 / Air King | PD ID 2280666 (Qualified 2016-10-04) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (35 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.3 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit Air King LEDAK50?
Calculated coverage metrics translate Air King LEDAK50 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 35 sq ft | 1 CFM/sq ft @ 35 CFM |
| Tall Bath (9-ft Ceiling) | Up to 31 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 99.9 kWh/yr (~$15.98/yr) | 11.4 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Air King LEDAK50?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ ANP50 | 50 / 42.3 CFM | 0.4 sones (+0.10) | 4.0 CFM/W | 4 in. diameter |
| Cyclone CBP50 | 50 / 42.3 CFM | 0.4 sones (+0.10) | 4.0 CFM/W | 4 in. diameter |
| S&P PC50XP | 50 / 42.3 CFM | 0.4 sones (+0.10) | 4.0 CFM/W | 4 in. diameter |
| Ortech ODE-5004 | 50 / 43.6 CFM | 0.4 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
| ACIQ AP50 | 50 / 42.3 CFM | 0.4 sones (+0.10) | 3.3 CFM/W | 4 in. diameter |
Does Air King LEDAK50 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Air King LEDAK50 percentage capacity without sending data.
Where should contractors skip Air King LEDAK50 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Air King LEDAK50 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Supplementary continuous trickle ventilation
- Works well for: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Air King LEDAK50?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Air King LEDAK50.
What duct and room conditions disqualify Air King LEDAK50?
Rule out Air King LEDAK50 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Air King LEDAK50 capacity?
Because static drag at 0.25 in. w.g. lowers Air King LEDAK50 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Air King LEDAK50 compared with a standard 3.0 sone builder fan?
Tested at 0.3 sones, Air King LEDAK50 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Air King LEDAK50 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Air King LEDAK50 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Air King LEDAK50 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King LEDAK50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King LEDAK50?
Air King LEDAK50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King LEDAK50's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King LEDAK50's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Air King LEDAK50 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Air King LEDAK50 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)