Skip to main content
Grant Estimator

Ortech ODE-5004 Exhaust Fan Specifications

ENERGY STAR PD #2731994 · Bathroom/Utility Room · Qualified 2023-09-29
Verified Specification Summary

Certified by EPA ENERGY STAR, Ortech ODE-5004 delivers 50 CFM free-air (43.6 CFM at 0.25 in. w.g.) and registers #50 of 607 in quietness (0.4 sones) and delivers 3.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 43 sq ft (8-ft height) or 38 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODE-5004 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 43.6 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
3.4 CFM/W (#1,060/1,145)
Static Retention
87.2% @ 0.25"
Motor Draw
14.7 W (5.4 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech ODE-5004 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 43.6 CFM out of 50 CFM (87.2% retention, 0.5 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Ortech maintains 27 active ENERGY STAR blowers; ODE-5004 (series: ODE-5004) (PD #2731994) gained qualification on 2023-09-29. Lighting kit: No. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 14.7 watts, about 5.4 kWh/yr (~$0.86/yr at $0.16/kWh) for 1 hr/day shower timers or 128.8 kWh/yr (~$20.61/yr) continuously. Closest competing matches include ACIQ AP50 (50.0 CFM) and ACIQ ANP50 (50.0 CFM).

How noisy is Ortech ODE-5004 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Ortech ODE-5004 measures 0.4 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

Why does rigid 4 in. diameter ducting protect Ortech ODE-5004 airflow?

Connecting Ortech ODE-5004 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Ortech ODE-5004 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODE-5004 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series ODE-5004 / ODE-5004 PD ID 2731994 (Qualified 2023-09-29)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (43.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Ortech ODE-5004?

Calculated coverage metrics translate Ortech ODE-5004 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Ortech ODE-5004
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 43 sq ft1 CFM/sq ft @ 43.6 CFM
Tall Bath (9-ft Ceiling)Up to 38 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.4 kWh/yr (~$0.86/yr)14.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2128.8 kWh/yr (~$20.61/yr)14.7 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Ortech ODE-5004?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ AP50 50 / 42.3 CFM 0.4 sones (Same) 3.3 CFM/W 4 in. diameter
ACIQ ANP50 50 / 42.3 CFM 0.4 sones (Same) 4.0 CFM/W 4 in. diameter
Cyclone CBP50 50 / 42.3 CFM 0.4 sones (Same) 4.0 CFM/W 4 in. diameter
S&P PC50XP 50 / 42.3 CFM 0.4 sones (Same) 4.0 CFM/W 4 in. diameter
Broan AE50 50 / 51.9 CFM 0.5 sones (+0.10) 3.5 CFM/W 4 in. diameter

Does Ortech ODE-5004 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODE-5004 percentage capacity without sending data.

Does Ortech ODE-5004 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Ortech ODE-5004 for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Supplementary continuous trickle ventilation
  • Best application: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Ortech ODE-5004?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODE-5004.

Does duct resistance cut Ortech ODE-5004 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Ortech ODE-5004 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Ortech ODE-5004 occupy in EPA filings?

With 0.4 sones at 0.1 in. w.g., Ortech ODE-5004 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does Ortech ODE-5004 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Ortech ODE-5004 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Ortech ODE-5004 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODE-5004's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech ODE-5004?

Ortech ODE-5004 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech ODE-5004's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODE-5004's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Ortech ODE-5004 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Ortech ODE-5004 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Ortech ODE-5004 in a bathroom remodel?

Avoid specifying Ortech ODE-5004 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories