Skip to main content
Grant Estimator

Broan QTXEG080X = QTXEGH with QTXEG080FX Exhaust Fan Specifications

ENERGY STAR PD #4008355 · Bathroom/Utility Room · Qualified 2025-02-07
Verified Specification Summary

Certified by EPA ENERGY STAR, Broan QTXEG080X = QTXEGH with QTXEG080FX delivers 80 CFM free-air (85.6 CFM at 0.25 in. w.g.) and registers #50 of 607 in quietness (0.4 sones) and delivers 4.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 85 sq ft (8-ft height) or 76 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QTXEG080X = QTXEGH with QTXEG080FX Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
80 / 85.6 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
107.0% @ 0.25"
Motor Draw
17.0 W (6.2 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan QTXEG080X = QTXEGH with QTXEG080FX vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 85.6 CFM out of 80 CFM (107.0% retention, 19.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #4008355 verifies QTXEG080X = QTXEGH with QTXEG080FX (series: QT SERIES) under Broan (207 listed models, qualified 2025-02-07). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include AERO PURE ABF80G15W (80.0 CFM) and AERO PURE ABF80G16W (80.0 CFM).

How noisy is Broan QTXEG080X = QTXEGH with QTXEG080FX compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Broan QTXEG080X = QTXEGH with QTXEG080FX measures 0.4 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

Why does rigid 6 in. diameter ducting protect Broan QTXEG080X = QTXEGH with QTXEG080FX airflow?

Connecting Broan QTXEG080X = QTXEGH with QTXEG080FX through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Broan QTXEG080X = QTXEGH with QTXEG080FX performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan QTXEG080X = QTXEGH with QTXEG080FX lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series QTXEG080X = QTXEGH with QTXEG080FX / QT SERIES PD ID 4008355 (Qualified 2025-02-07)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (85.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Broan QTXEG080X = QTXEGH with QTXEG080FX?

Calculated coverage metrics translate Broan QTXEG080X = QTXEGH with QTXEG080FX airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Broan QTXEG080X = QTXEGH with QTXEG080FX
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 85 sq ft1 CFM/sq ft @ 85.6 CFM
Tall Bath (9-ft Ceiling)Up to 76 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 35 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.2 kWh/yr (~$0.99/yr)17.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2148.9 kWh/yr (~$23.82/yr)17.0 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Broan QTXEG080X = QTXEGH with QTXEG080FX?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
AERO PURE ABF80G15W 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
AERO PURE ABF80G16W 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
AUPU AV08A1 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
Air King AK80LS6 80 / 59.6 CFM 0.5 sones (+0.10) 4.7 CFM/W 6 in. diameter
Air King AK80LS6H 80 / 59.6 CFM 0.5 sones (+0.10) 4.7 CFM/W 6 in. diameter

Does Broan QTXEG080X = QTXEGH with QTXEG080FX match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan QTXEG080X = QTXEGH with QTXEG080FX percentage capacity without sending data.

Does Broan QTXEG080X = QTXEGH with QTXEG080FX suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan QTXEG080X = QTXEGH with QTXEG080FX for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 35 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 85.6 CFM net static output
  • Best application: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Broan QTXEG080X = QTXEGH with QTXEG080FX?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan QTXEG080X = QTXEGH with QTXEG080FX.

What acoustic sone tier does Broan QTXEG080X = QTXEGH with QTXEG080FX occupy in EPA filings?

With 0.4 sones at 0.1 in. w.g., Broan QTXEG080X = QTXEGH with QTXEG080FX operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does Broan QTXEG080X = QTXEGH with QTXEG080FX add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan QTXEG080X = QTXEGH with QTXEG080FX averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan QTXEG080X = QTXEGH with QTXEG080FX pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QTXEG080X = QTXEGH with QTXEG080FX's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan QTXEG080X = QTXEGH with QTXEG080FX?

Broan QTXEG080X = QTXEGH with QTXEG080FX features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan QTXEG080X = QTXEGH with QTXEG080FX's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QTXEG080X = QTXEGH with QTXEG080FX's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan QTXEG080X = QTXEGH with QTXEG080FX pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan QTXEG080X = QTXEGH with QTXEG080FX easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan QTXEG080X = QTXEGH with QTXEG080FX in a bathroom remodel?

Avoid specifying Broan QTXEG080X = QTXEGH with QTXEG080FX in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan QTXEG080X = QTXEGH with QTXEG080FX airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan QTXEG080X = QTXEGH with QTXEG080FX achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories