Rated for 70 CFM open-air (60.6 CFM at 0.25 in. w.g.), Hampton Bay BF70HD registers #522 of 607 in quietness (2.0 sones) and delivers 3.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 60 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Hampton Bay BF70HD Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 60.6 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 3.4 CFM/W (#1,060/1,145)
- Static Retention
- 86.6% @ 0.25"
- Motor Draw
- 20.6 W (7.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Hampton Bay BF70HD vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.6 CFM out of 70 CFM (86.6% retention, 1.1 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Hampton Bay's 4-unit lineup, BF70HD (series: Hampton Bay) carries PD #2369239 dating to 2020-11-06. Lighting kit: No. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.6 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 180.5 kWh/yr (~$28.88/yr) continuously. Closest competing matches include Air King BFQ75 (70.0 CFM) and Air King WM70 (70.0 CFM).
How does Hampton Bay BF70HD acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Hampton Bay BF70HD (2.0 sones).
How do flex elbows choke Hampton Bay BF70HD at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Hampton Bay BF70HD moving full rated CFM.
Does Hampton Bay BF70HD meet residential exhaust fan code specs?
Inspect Hampton Bay BF70HD mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Hampton Bay (4 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BF70HD / Hampton Bay | PD ID 2369239 (Qualified 2020-11-06) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (60.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Hampton Bay BF70HD airflow output?
Annual electricity figures and room square-footage ceilings below reflect Hampton Bay BF70HD tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 180.5 kWh/yr (~$28.88/yr) | 20.6 W x 8,760 hrs / 1,000 |
Which competing models share Hampton Bay BF70HD airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Air King BFQ75 | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| Air King WM70 | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7140-70-HW | 70 / 51.7 CFM | 2.0 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| PROJECT SOURCE 7140-70-PS | 70 / 51.7 CFM | 2.0 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| PROJECT SOURCE 8771-70-PS | 70 / 51.7 CFM | 2.0 sones (Same) | 3.3 CFM/W | 4 in. diameter |
How much airflow margin does Hampton Bay BF70HD give your bath?
Run a quick local room-volume check for Hampton Bay BF70HD by entering square footage and ceiling height to spot under-vented steam risks early.
Does Hampton Bay BF70HD suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Hampton Bay BF70HD for your remodel.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 60 sq ft with 8-ft ceilings (53 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Hampton Bay BF70HD?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Hampton Bay BF70HD.
Who should NOT install Hampton Bay BF70HD in a bathroom remodel?
Avoid specifying Hampton Bay BF70HD in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Hampton Bay BF70HD airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Hampton Bay BF70HD achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Hampton Bay BF70HD occupy in EPA filings?
With 2.0 sones at 0.1 in. w.g., Hampton Bay BF70HD produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Hampton Bay BF70HD add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Hampton Bay BF70HD averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Hampton Bay BF70HD pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Hampton Bay BF70HD's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Hampton Bay BF70HD?
Hampton Bay BF70HD features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Hampton Bay BF70HD's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Hampton Bay BF70HD's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Hampton Bay BF70HD pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Hampton Bay BF70HD easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)