Delta SLM70H Exhaust Fan Specifications

ENERGY STAR PD #2254283 · Bathroom/Utility Room · Qualified 2015-12-01
Verified Specification Summary

Rated for 70 CFM open-air (58.7 CFM at 0.25 in. w.g.), Delta SLM70H registers #522 of 607 in quietness (2.0 sones) and delivers 5.8 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 58 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM70H Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
70 / 58.7 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
5.8 CFM/W (#461/1,145)
Static Retention
83.9% @ 0.25"
Motor Draw
12.1 W (4.4 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta SLM70H vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 58.7 CFM at 0.25 in. w.g. (83.9% retention, 3.8 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta SLM70H (series: BreezSlim) under PD #2254283 (121 models registered, 2015-12-01). Lighting kit: No. At 5.8 CFM/W (#461 of 1,145, top 40.7% of 1,145 rated models, more efficient than 59.3% of rated models, 1.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.1 watts, about 4.4 kWh/yr (~$0.70/yr at $0.16/kWh) for 1 hr/day shower timers or 106.0 kWh/yr (~$16.96/yr) continuously. Closest competing matches include Utilitech 7111-04-L (70.0 CFM) and Revent RVL70 (70.0 CFM).

How does Delta SLM70H acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Delta SLM70H (2.0 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

How do flex elbows choke Delta SLM70H at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Delta SLM70H moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Delta SLM70H meet residential exhaust fan code specs?

Inspect Delta SLM70H mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series SLM70H / BreezSlim PD ID 2254283 (Qualified 2015-12-01)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (58.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Delta SLM70H airflow output?

Annual electricity figures and room square-footage ceilings below reflect Delta SLM70H tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Delta SLM70H
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 58 sq ft1 CFM/sq ft @ 58.7 CFM
Tall Bath (9-ft Ceiling)Up to 52 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.4 kWh/yr (~$0.70/yr)12.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2106.0 kWh/yr (~$16.96/yr)12.1 W x 8,760 hrs / 1,000

Which competing models share Delta SLM70H airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech 7111-04-L 70 / 56.5 CFM 2.0 sones (Same) 7.0 CFM/W 3 in. diameter
Revent RVL70 70 / 72.3 CFM 2.0 sones (Same) 7.7 CFM/W 4 in. diameter
Revent RVLH70 70 / 72.3 CFM 2.0 sones (Same) 7.7 CFM/W 4 in. diameter
Broan BEL7A 70 / 57.4 CFM 2.0 sones (Same) 3.8 CFM/W 4 in. diameter
HomeWerks Worldwide 299650A 70 / 58.9 CFM 2.0 sones (Same) 3.8 CFM/W 3 in. diameter

How much airflow margin does Delta SLM70H give your bath?

Run a quick local room-volume check for Delta SLM70H by entering square footage and ceiling height to spot under-vented steam risks early.

Does Delta SLM70H suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Delta SLM70H for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 58 sq ft with 8-ft ceilings (52 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 3 in. diameter

What should homeowners verify first about Delta SLM70H?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta SLM70H.

How many kWh per year does Delta SLM70H add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Delta SLM70H averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Delta SLM70H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM70H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta SLM70H?

Delta SLM70H features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta SLM70H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM70H's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Delta SLM70H pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Delta SLM70H easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Delta SLM70H in a bathroom remodel?

Avoid specifying Delta SLM70H in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Delta SLM70H airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Delta SLM70H achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Delta SLM70H occupy in EPA filings?

With 2.0 sones at 0.1 in. w.g., Delta SLM70H produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.