The Revent RVL70 (ReVent) moves 70 CFM at 0.1 in. w.g. (72.3 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones), and delivers 7.7 CFM/W efficacy, sizing bathrooms up to 72 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVL70 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 72.3 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 7.7 CFM/W (#377/1,145)
- Static Retention
- 103.3% @ 0.25"
- Motor Draw
- 9.1 W (3.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Revent RVL70 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 72.3 CFM out of 70 CFM (103.3% retention, 15.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #4470612 verifies RVL70 (series: ReVent) under Revent (40 listed models, qualified 2025-06-20). Lighting kit: Yes. At 7.7 CFM/W (#377 of 1,145, top 33.1% of 1,145 rated models, more efficient than 66.9% of rated models, 3.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.1 watts, about 3.3 kWh/yr (~$0.53/yr at $0.16/kWh) for 1 hr/day shower timers or 79.7 kWh/yr (~$12.75/yr) continuously. Closest competing matches include Utilitech UTL506070 (70.0 CFM) and Utilitech UTS506070 (70.0 CFM).
Where does Revent RVL70 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 2.0 sones against all 1,145 EPA listings.
How does duct geometry alter Revent RVL70 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Revent RVL70?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Revent RVL70 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Revent (40 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RVL70 / ReVent | PD ID 4470612 (Qualified 2025-06-20) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (72.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Revent RVL70 ventilate safely?
Sizing outputs below convert Revent RVL70 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 72 sq ft | 1 CFM/sq ft @ 72.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 64 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 22 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.3 kWh/yr (~$0.53/yr) | 9.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 79.7 kWh/yr (~$12.75/yr) | 9.1 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Revent RVL70 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTL506070 | 70 / 78.6 CFM | Unpublished | 8.1 CFM/W | 4 in. diameter |
| Utilitech UTS506070 | 70 / 79 CFM | Unpublished | 8.2 CFM/W | 4 in. diameter |
| Delta SLM70D | 70 / 56.1 CFM | Unpublished | 7.0 CFM/W | 3 in. diameter |
| Delta SLM70D2 | 70 / 60.5 CFM | Unpublished | 7.0 CFM/W | 3 in. diameter |
| Utilitech 7111-04-L | 70 / 56.5 CFM | 2.0 sones (Same) | 7.0 CFM/W | 3 in. diameter |
Will Revent RVL70 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Revent RVL70 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Who should not install Revent RVL70 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Revent RVL70 for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 22 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 72 sq ft with 8-ft ceilings (64 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Revent RVL70?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Revent RVL70.
When is Revent RVL70 undersized or poorly matched for a bath renovation?
Skip Revent RVL70 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Revent RVL70 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Revent RVL70 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Revent RVL70 sound output compare to noisy contractor-grade fans?
Rated at 2.0 sones, Revent RVL70 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Revent RVL70?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Revent RVL70 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVL70's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Revent RVL70?
Revent RVL70 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Revent RVL70's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVL70's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Revent RVL70 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Revent RVL70 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)