The Revent RVLH70 (ReVent) moves 70 CFM at 0.1 in. w.g. (72.3 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones), and delivers 7.7 CFM/W efficacy, sizing bathrooms up to 72 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVLH70 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 72.3 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 7.7 CFM/W (#377/1,145)
- Static Retention
- 103.3% @ 0.25"
- Motor Draw
- 9.1 W (3.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Revent RVLH70 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 72.3 CFM out of 70 CFM (103.3% retention, 15.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Revent maintains 40 active ENERGY STAR blowers; RVLH70 (series: ReVent) (PD #4470615) gained qualification on 2025-06-20. Lighting kit: Yes. At 7.7 CFM/W (#377 of 1,145, top 33.1% of 1,145 rated models, more efficient than 66.9% of rated models, 3.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.1 watts, about 3.3 kWh/yr (~$0.53/yr at $0.16/kWh) for 1 hr/day shower timers or 79.7 kWh/yr (~$12.75/yr) continuously. Closest competing matches include Utilitech UTL506070 (70.0 CFM) and Utilitech UTS506070 (70.0 CFM).
Where does Revent RVLH70 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 2.0 sones against all 1,145 EPA listings.
How does duct geometry alter Revent RVLH70 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Revent RVLH70?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Revent RVLH70 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Revent (40 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RVLH70 / ReVent | PD ID 4470615 (Qualified 2025-06-20) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (72.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Revent RVLH70 ventilate safely?
Sizing outputs below convert Revent RVLH70 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 72 sq ft | 1 CFM/sq ft @ 72.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 64 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 22 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.3 kWh/yr (~$0.53/yr) | 9.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 79.7 kWh/yr (~$12.75/yr) | 9.1 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Revent RVLH70 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTL506070 | 70 / 78.6 CFM | Unpublished | 8.1 CFM/W | 4 in. diameter |
| Utilitech UTS506070 | 70 / 79 CFM | Unpublished | 8.2 CFM/W | 4 in. diameter |
| Delta SLM70D | 70 / 56.1 CFM | Unpublished | 7.0 CFM/W | 3 in. diameter |
| Delta SLM70D2 | 70 / 60.5 CFM | Unpublished | 7.0 CFM/W | 3 in. diameter |
| Utilitech 7111-04-L | 70 / 56.5 CFM | 2.0 sones (Same) | 7.0 CFM/W | 3 in. diameter |
Will Revent RVLH70 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Revent RVLH70 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does Revent RVLH70 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Revent RVLH70.
Limitations & Who Should Skip
- Steam or walk-in tub room > 22 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 72 sq ft with 8-ft ceilings (64 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Revent RVLH70?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Revent RVLH70.
Does running Revent RVLH70 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Revent RVLH70 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Revent RVLH70 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVLH70's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Revent RVLH70?
Revent RVLH70 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Revent RVLH70's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVLH70's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Revent RVLH70 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Revent RVLH70 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Revent RVLH70?
Do not force Revent RVLH70 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Revent RVLH70 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Revent RVLH70 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Revent RVLH70 disturb adjacent bedrooms during night use?
Acoustic measurement places Revent RVLH70 at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)