In EPA dataset 8dv7-nngq, Delta SLM70ELED tests at 70 CFM free discharge (55.1 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 6.0 CFM/W efficacy, meeting residential IRC M1505 sizing up to 55 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM70ELED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 55.1 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 6.0 CFM/W (#459/1,145)
- Static Retention
- 78.7% @ 0.25"
- Motor Draw
- 11.7 W (4.3 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Delta SLM70ELED vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 70 CFM open-air to 55.1 CFM at 0.25 in. w.g. (78.7% retention, 9.0 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Delta registers 121 certified models, with SKU SLM70ELED (series: BreezSlim) (PD #2364227) certified since 2020-08-07. Lighting kit: Yes. At 6.0 CFM/W (#459 of 1,145, top 40.1% of 1,145 rated models, more efficient than 59.9% of rated models, 1.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.7 watts, about 4.3 kWh/yr (~$0.69/yr at $0.16/kWh) for 1 hr/day shower timers or 102.5 kWh/yr (~$16.40/yr) continuously. Closest competing matches include Utilitech 7111-04-L (70.0 CFM) and Revent RVL70 (70.0 CFM).
Does Delta SLM70ELED fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Delta SLM70ELED at 2.0 sones.
Why avoid unvented attic termination with Delta SLM70ELED?
Under ASHRAE 62.2 best practice, Delta SLM70ELED needs insulated 3 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Delta SLM70ELED?
Before cutting ceiling drywall or sizing attic transitions for Delta SLM70ELED, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SLM70ELED / BreezSlim | PD ID 2364227 (Qualified 2020-08-07) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (55.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Delta SLM70ELED?
Bathroom ventilation sizing below maps Delta SLM70ELED motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 55 sq ft | 1 CFM/sq ft @ 55.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 48 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.3 kWh/yr (~$0.69/yr) | 11.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 102.5 kWh/yr (~$16.40/yr) | 11.7 W x 8,760 hrs / 1,000 |
What peer models sit nearest Delta SLM70ELED in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta SLM70ELED.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7111-04-L | 70 / 56.5 CFM | 2.0 sones (Same) | 7.0 CFM/W | 3 in. diameter |
| Revent RVL70 | 70 / 72.3 CFM | 2.0 sones (Same) | 7.7 CFM/W | 4 in. diameter |
| Revent RVLH70 | 70 / 72.3 CFM | 2.0 sones (Same) | 7.7 CFM/W | 4 in. diameter |
| Revent RVS70 | 70 / 76 CFM | 2.0 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| Revent RVSH70 | 70 / 76 CFM | 2.0 sones (Same) | 7.8 CFM/W | 4 in. diameter |
What percentage of room demand does Delta SLM70ELED cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta SLM70ELED tested delivery.
When does Delta SLM70ELED fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta SLM70ELED.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 55.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around 2.0 sones up to 55 sq ft
- Target scenario: Paired with rigid galvanized 3 in. diameter transition
Where do official rules set limits for Delta SLM70ELED?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta SLM70ELED.
Which bathroom layouts should pick a larger blower than Delta SLM70ELED?
Do not force Delta SLM70ELED into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Delta SLM70ELED retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Delta SLM70ELED produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.
Will Delta SLM70ELED disturb adjacent bedrooms during night use?
Acoustic measurement places Delta SLM70ELED at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Delta SLM70ELED continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Delta SLM70ELED draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Delta SLM70ELED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM70ELED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta SLM70ELED?
Delta SLM70ELED features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta SLM70ELED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM70ELED's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Delta SLM70ELED code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta SLM70ELED clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)