In EPA dataset 8dv7-nngq, Milano TY-110-ESL tests at 110 CFM free discharge (94.2 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 3.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 94 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Milano TY-110-ESL Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 94.2 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 85.6% @ 0.25"
- Motor Draw
- 28.2 W (10.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Milano TY-110-ESL vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.2 CFM out of 110 CFM (85.6% retention, 2.1 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places TY-110-ESL (series: TY-110-ESL) (PD #3891063) among 6 Milano entries qualified through 2024-11-08. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.2 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.0 kWh/yr (~$39.52/yr) continuously. Closest competing matches include HomeWerks Worldwide 7107-03HW (110.0 CFM) and Broan AE110 (110.0 CFM).
Does Milano TY-110-ESL fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Milano TY-110-ESL at 1.0 sones.
Why avoid unvented attic termination with Milano TY-110-ESL?
Under ASHRAE 62.2 best practice, Milano TY-110-ESL needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Milano TY-110-ESL?
Before cutting ceiling drywall or sizing attic transitions for Milano TY-110-ESL, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Milano (6 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TY-110-ESL / TY-110-ESL | PD ID 3891063 (Qualified 2024-11-08) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (94.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Milano TY-110-ESL?
Bathroom ventilation sizing below maps Milano TY-110-ESL motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.3 kWh/yr (~$1.65/yr) | 28.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 247.0 kWh/yr (~$39.52/yr) | 28.2 W x 8,760 hrs / 1,000 |
What peer models sit nearest Milano TY-110-ESL in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Milano TY-110-ESL.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| HomeWerks Worldwide 7107-03HW | 110 / 96 CFM | 1.0 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Broan AE110 | 110 / 95.5 CFM | 1.0 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Broan AE110 = A000HFKT with AE110F1 | 110 / 95.5 CFM | 1.0 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Broan AE110 = A000HFNF with AE110F1 | 110 / 95.5 CFM | 1.0 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Broan AE110K | 110 / 95.5 CFM | 1.0 sones (Same) | 4.3 CFM/W | 4 in. diameter |
What percentage of room demand does Milano TY-110-ESL cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Milano TY-110-ESL tested delivery.
Where should contractors skip Milano TY-110-ESL on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Milano TY-110-ESL carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 94.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around 1.0 sones up to 94 sq ft
- Works well for: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Milano TY-110-ESL?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Milano TY-110-ESL.
Will long attic ducting choke Milano TY-110-ESL capacity?
Because static drag at 0.25 in. w.g. lowers Milano TY-110-ESL from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Milano TY-110-ESL compared with a standard 3.0 sone builder fan?
Tested at 1.0 sones, Milano TY-110-ESL operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Milano TY-110-ESL consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Milano TY-110-ESL draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Milano TY-110-ESL pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Milano TY-110-ESL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Milano TY-110-ESL?
Milano TY-110-ESL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Milano TY-110-ESL's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Milano TY-110-ESL's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Milano TY-110-ESL score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Milano TY-110-ESL delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Milano TY-110-ESL?
Rule out Milano TY-110-ESL when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)