Skip to main content
Grant Estimator

Milano TY-110-ESL Exhaust Fan Specifications

ENERGY STAR PD #3891063 · Bathroom/Utility Room · Qualified 2024-11-08
Verified Specification Summary

In EPA dataset 8dv7-nngq, Milano TY-110-ESL tests at 110 CFM free discharge (94.2 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 3.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 94 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Milano TY-110-ESL Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 94.2 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
85.6% @ 0.25"
Motor Draw
28.2 W (10.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Milano TY-110-ESL vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.2 CFM out of 110 CFM (85.6% retention, 2.1 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places TY-110-ESL (series: TY-110-ESL) (PD #3891063) among 6 Milano entries qualified through 2024-11-08. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.2 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.0 kWh/yr (~$39.52/yr) continuously. Closest competing matches include HomeWerks Worldwide 7107-03HW (110.0 CFM) and Broan AE110 (110.0 CFM).

Does Milano TY-110-ESL fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Milano TY-110-ESL at 1.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why avoid unvented attic termination with Milano TY-110-ESL?

Under ASHRAE 62.2 best practice, Milano TY-110-ESL needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Milano TY-110-ESL?

Before cutting ceiling drywall or sizing attic transitions for Milano TY-110-ESL, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Milano (6 models) ENERGY STAR Certified Partner
Model Number & Series TY-110-ESL / TY-110-ESL PD ID 3891063 (Qualified 2024-11-08)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (94.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Milano TY-110-ESL?

Bathroom ventilation sizing below maps Milano TY-110-ESL motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Milano TY-110-ESL
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 94 sq ft1 CFM/sq ft @ 94.2 CFM
Tall Bath (9-ft Ceiling)Up to 83 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 44 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.3 kWh/yr (~$1.65/yr)28.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2247.0 kWh/yr (~$39.52/yr)28.2 W x 8,760 hrs / 1,000

What peer models sit nearest Milano TY-110-ESL in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Milano TY-110-ESL.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
HomeWerks Worldwide 7107-03HW 110 / 96 CFM 1.0 sones (Same) 4.1 CFM/W 4 in. diameter
Broan AE110 110 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
Broan AE110 = A000HFKT with AE110F1 110 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
Broan AE110 = A000HFNF with AE110F1 110 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
Broan AE110K 110 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter

What percentage of room demand does Milano TY-110-ESL cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Milano TY-110-ESL tested delivery.

Where should contractors skip Milano TY-110-ESL on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Milano TY-110-ESL carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 94.2 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around 1.0 sones up to 94 sq ft
  • Works well for: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Milano TY-110-ESL?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Milano TY-110-ESL.

Will long attic ducting choke Milano TY-110-ESL capacity?

Because static drag at 0.25 in. w.g. lowers Milano TY-110-ESL from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Milano TY-110-ESL compared with a standard 3.0 sone builder fan?

Tested at 1.0 sones, Milano TY-110-ESL operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Milano TY-110-ESL consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Milano TY-110-ESL draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Milano TY-110-ESL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Milano TY-110-ESL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Milano TY-110-ESL?

Milano TY-110-ESL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Milano TY-110-ESL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Milano TY-110-ESL's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Milano TY-110-ESL score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Milano TY-110-ESL delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Milano TY-110-ESL?

Rule out Milano TY-110-ESL when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories