Rated for 100 CFM open-air (82.7 CFM at 0.25 in. w.g.), Air King AK100LS6H registers #265 of 607 in quietness (1.0 sones) and delivers 3.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 82 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK100LS6H Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 82.7 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 82.7% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Air King AK100LS6H vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 100 CFM open-air to 82.7 CFM at 0.25 in. w.g. (82.7% retention, 5.0 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Inside Air King's 62-unit lineup, AK100LS6H (series: Air King) carries PD #2395006 dating to 2022-04-22. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Broan AE100B = A000HFKT with AE100BF1 (100.0 CFM) and Broan AE100B = A000HFNF with AE100BF1 (100.0 CFM).
How does Air King AK100LS6H acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Air King AK100LS6H (1.0 sones).
How do flex elbows choke Air King AK100LS6H at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Air King AK100LS6H moving full rated CFM.
Does Air King AK100LS6H meet residential exhaust fan code specs?
Inspect Air King AK100LS6H mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK100LS6H / Air King | PD ID 2395006 (Qualified 2022-04-22) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (82.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Air King AK100LS6H airflow output?
Annual electricity figures and room square-footage ceilings below reflect Air King AK100LS6H tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 82 sq ft | 1 CFM/sq ft @ 82.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 73 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 32 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
Which competing models share Air King AK100LS6H airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan AE100B = A000HFKT with AE100BF1 | 100 / 95.5 CFM | 1.0 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Broan AE100B = A000HFNF with AE100BF1 | 100 / 95.5 CFM | 1.0 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Good Housekeeping 84005 | 100 / 92.3 CFM | 1.0 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| VOTATEC VO-FN4W26-AC-100 | 100 / 85 CFM | 0.9 sones (-0.10) | 3.9 CFM/W | 4 in. diameter |
| Wintek BPT15B-100H1 | 100 / 85 CFM | 0.9 sones (-0.10) | 3.9 CFM/W | 4 in. diameter |
How much airflow margin does Air King AK100LS6H give your bath?
Run a quick local room-volume check for Air King AK100LS6H by entering square footage and ceiling height to spot under-vented steam risks early.
Who should not install Air King AK100LS6H in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Air King AK100LS6H for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 32 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 82 sq ft with 8-ft ceilings (73 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Air King AK100LS6H?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Air King AK100LS6H.
Why check Air King AK100LS6H CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Air King AK100LS6H registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.
How does Air King AK100LS6H sound output compare to noisy contractor-grade fans?
Rated at 1.0 sones, Air King AK100LS6H operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Air King AK100LS6H?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Air King AK100LS6H pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK100LS6H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King AK100LS6H?
Air King AK100LS6H features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King AK100LS6H's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK100LS6H's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Air King AK100LS6H satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Air King AK100LS6H clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Air King AK100LS6H undersized or poorly matched for a bath renovation?
Skip Air King AK100LS6H if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)