The Broan AE100B = A000HFKT with AE100BF1 (INVENT) moves 100 CFM at 0.1 in. w.g. (95.5 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 4.3 CFM/W efficacy, sizing bathrooms up to 95 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE100B = A000HFKT with AE100BF1 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 95.5 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 95.5% @ 0.25"
- Motor Draw
- 23.3 W (8.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan AE100B = A000HFKT with AE100BF1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.5 CFM out of 100 CFM (95.5% retention, 7.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Broan AE100B = A000HFKT with AE100BF1 (series: INVENT) under PD #4708499 (207 models registered, 2026-09-23). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 23.3 watts, about 8.5 kWh/yr (~$1.36/yr at $0.16/kWh) for 1 hr/day shower timers or 204.1 kWh/yr (~$32.66/yr) continuously. Closest competing matches include Air King BFC100 (100.0 CFM) and Air King BFC100H (100.0 CFM).
Where does Broan AE100B = A000HFKT with AE100BF1 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.
How does duct geometry alter Broan AE100B = A000HFKT with AE100BF1 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Broan AE100B = A000HFKT with AE100BF1?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan AE100B = A000HFKT with AE100BF1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE100B = A000HFKT with AE100BF1 / INVENT | PD ID 4708499 (Qualified 2026-09-23) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (95.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Broan AE100B = A000HFKT with AE100BF1 ventilate safely?
Sizing outputs below convert Broan AE100B = A000HFKT with AE100BF1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 95 sq ft | 1 CFM/sq ft @ 95.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 84 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 45 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.5 kWh/yr (~$1.36/yr) | 23.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 204.1 kWh/yr (~$32.66/yr) | 23.3 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Broan AE100B = A000HFKT with AE100BF1 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Air King BFC100 | 100 / 86.5 CFM | 1.0 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Air King BFC100H | 100 / 86.5 CFM | 1.0 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Good Housekeeping 84005 | 100 / 92.3 CFM | 1.0 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Air King AK100LS6 | 100 / 82.7 CFM | 1.0 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| Air King AK100LS6H | 100 / 82.7 CFM | 1.0 sones (Same) | 3.9 CFM/W | 6 in. diameter |
Will Broan AE100B = A000HFKT with AE100BF1 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Broan AE100B = A000HFKT with AE100BF1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Does Broan AE100B = A000HFKT with AE100BF1 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan AE100B = A000HFKT with AE100BF1 for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 45 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 95 sq ft with 8-ft ceilings (84 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Broan AE100B = A000HFKT with AE100BF1?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan AE100B = A000HFKT with AE100BF1.
What acoustic sone tier does Broan AE100B = A000HFKT with AE100BF1 occupy in EPA filings?
With 1.0 sones at 0.1 in. w.g., Broan AE100B = A000HFKT with AE100BF1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does Broan AE100B = A000HFKT with AE100BF1 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Broan AE100B = A000HFKT with AE100BF1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Broan AE100B = A000HFKT with AE100BF1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE100B = A000HFKT with AE100BF1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE100B = A000HFKT with AE100BF1?
Broan AE100B = A000HFKT with AE100BF1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE100B = A000HFKT with AE100BF1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE100B = A000HFKT with AE100BF1's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan AE100B = A000HFKT with AE100BF1 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan AE100B = A000HFKT with AE100BF1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Broan AE100B = A000HFKT with AE100BF1 in a bathroom remodel?
Avoid specifying Broan AE100B = A000HFKT with AE100BF1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Broan AE100B = A000HFKT with AE100BF1 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan AE100B = A000HFKT with AE100BF1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)