Air King BFC100H Exhaust Fan Specifications

ENERGY STAR PD #2383438 · Bathroom/Utility Room · Qualified 2021-08-13
Verified Specification Summary

Homeowners specifying Air King BFC100H gain 100 CFM at 0.1 in. w.g. (86.5 CFM at 0.25 in. w.g.) where it registers #265 of 607 in quietness (1.0 sones) and delivers 4.5 CFM/W efficacy, venting bathrooms up to 86 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King BFC100H Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 86.5 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
4.5 CFM/W (#632/1,145)
Static Retention
86.5% @ 0.25"
Motor Draw
22.2 W (8.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King BFC100H vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 86.5 CFM out of 100 CFM (86.5% retention, 1.2 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Air King maintains 62 active ENERGY STAR blowers; BFC100H (series: Air King) (PD #2383438) gained qualification on 2021-08-13. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.2 watts, about 8.1 kWh/yr (~$1.30/yr at $0.16/kWh) for 1 hr/day shower timers or 194.5 kWh/yr (~$31.12/yr) continuously. Closest competing matches include Good Housekeeping 84005 (100.0 CFM) and Broan AE100B = A000HFKT with AE100BF1 (100.0 CFM).

What acoustic percentile does Air King BFC100H occupy among 1,145 bath blowers?

Inspect how Air King BFC100H positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Which exterior damper path suits Air King BFC100H best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Air King BFC100H housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Air King BFC100H acoustic and static metrics stand?

Compare Air King BFC100H published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series BFC100H / Air King PD ID 2383438 (Qualified 2021-08-13)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (86.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Air King BFC100H handle taller ceilings or walk-in tub steam?

Evaluate how Air King BFC100H scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Air King BFC100H
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 86 sq ft1 CFM/sq ft @ 86.5 CFM
Tall Bath (9-ft Ceiling)Up to 76 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 36 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.1 kWh/yr (~$1.30/yr)22.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2194.5 kWh/yr (~$31.12/yr)22.2 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Air King BFC100H?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Good Housekeeping 84005 100 / 92.3 CFM 1.0 sones (Same) 4.5 CFM/W 4 in. diameter
Broan AE100B = A000HFKT with AE100BF1 100 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
Broan AE100B = A000HFNF with AE100BF1 100 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
ARTIKA FAB-BRLU-C1 100 / 95.3 CFM 0.9 sones (-0.10) 4.5 CFM/W 4 in. diameter
Nektra 33003853 100 / 84.1 CFM 0.9 sones (-0.10) 4.1 CFM/W 4 in. diameter

Is Air King BFC100H sized right for your shower or tub room?

Check whether Air King BFC100H clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Which bath layouts should avoid specifying Air King BFC100H?

Match Air King BFC100H directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 36 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 86.5 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Air King BFC100H?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Air King BFC100H.

What does Air King BFC100H cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Air King BFC100H 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Air King BFC100H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King BFC100H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King BFC100H?

Air King BFC100H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King BFC100H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King BFC100H's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Air King BFC100H ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Air King BFC100H covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Air King BFC100H run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Air King BFC100H.

What happens to Air King BFC100H CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Air King BFC100H moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Air King BFC100H sit on acoustic comfort for senior homeowners?

Measuring 1.0 sones, Air King BFC100H operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories