In EPA dataset 8dv7-nngq, Air King BFC100 tests at 100 CFM free discharge (86.5 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 4.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 86 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King BFC100 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 86.5 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 86.5% @ 0.25"
- Motor Draw
- 22.2 W (8.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Air King BFC100 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 86.5 CFM out of 100 CFM (86.5% retention, 1.2 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places BFC100 (series: Air King) (PD #2383439) among 62 Air King entries qualified through 2021-08-13. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.2 watts, about 8.1 kWh/yr (~$1.30/yr at $0.16/kWh) for 1 hr/day shower timers or 194.5 kWh/yr (~$31.12/yr) continuously. Closest competing matches include Good Housekeeping 84005 (100.0 CFM) and Broan AE100B = A000HFKT with AE100BF1 (100.0 CFM).
Does Air King BFC100 fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Air King BFC100 at 1.0 sones.
Why avoid unvented attic termination with Air King BFC100?
Under ASHRAE 62.2 best practice, Air King BFC100 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Air King BFC100?
Before cutting ceiling drywall or sizing attic transitions for Air King BFC100, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BFC100 / Air King | PD ID 2383439 (Qualified 2021-08-13) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (86.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Air King BFC100?
Bathroom ventilation sizing below maps Air King BFC100 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 86 sq ft | 1 CFM/sq ft @ 86.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 76 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 36 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.1 kWh/yr (~$1.30/yr) | 22.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 194.5 kWh/yr (~$31.12/yr) | 22.2 W x 8,760 hrs / 1,000 |
What peer models sit nearest Air King BFC100 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Air King BFC100.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Good Housekeeping 84005 | 100 / 92.3 CFM | 1.0 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Broan AE100B = A000HFKT with AE100BF1 | 100 / 95.5 CFM | 1.0 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Broan AE100B = A000HFNF with AE100BF1 | 100 / 95.5 CFM | 1.0 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| ARTIKA FAB-BRLU-C1 | 100 / 95.3 CFM | 0.9 sones (-0.10) | 4.5 CFM/W | 4 in. diameter |
| Nektra 33003853 | 100 / 84.1 CFM | 0.9 sones (-0.10) | 4.1 CFM/W | 4 in. diameter |
What percentage of room demand does Air King BFC100 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Air King BFC100 tested delivery.
When does Air King BFC100 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Air King BFC100.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 86.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around 1.0 sones up to 86 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Air King BFC100?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Air King BFC100.
Is Air King BFC100 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Air King BFC100 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Air King BFC100?
Do not force Air King BFC100 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Air King BFC100 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Air King BFC100 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Air King BFC100 disturb adjacent bedrooms during night use?
Acoustic measurement places Air King BFC100 at 1.0 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Does running Air King BFC100 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Air King BFC100 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Air King BFC100 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King BFC100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King BFC100?
Air King BFC100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King BFC100's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King BFC100's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)