In EPA dataset 8dv7-nngq, Ortech ODD-70-1 tests at 75 CFM free discharge (62.3 CFM at 0.25 in. w.g.) and registers #50 of 607 in quietness (0.4 sones) and delivers 16.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 62 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODD-70-1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 75 / 62.3 CFM
- Noise @ 0.1"
- 0.4 sones (#50/607)
- Efficacy Rank
- 16.7 CFM/W (#1/1,145)
- Static Retention
- 83.1% @ 0.25"
- Motor Draw
- 4.5 W (1.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Ortech ODD-70-1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 75 CFM open-air to 62.3 CFM at 0.25 in. w.g. (83.1% retention, 4.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places ODD-70-1 (series: ODD-70-1) (PD #3557061) among 27 Ortech entries qualified through 2024-08-02. Lighting kit: No. At 16.7 CFM/W (#1 of 1,145, top 0.3% of 1,145 rated models, more efficient than 99.7% of rated models, 12.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 4.5 watts, about 1.6 kWh/yr (~$0.26/yr at $0.16/kWh) for 1 hr/day shower timers or 39.4 kWh/yr (~$6.30/yr) continuously. Closest competing matches include DewStop - Breeze Easy BES80 (80.0 CFM) and DewStop - Breeze Easy BEL80 (80.0 CFM).
Does Ortech ODD-70-1 fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Ortech ODD-70-1 at 0.4 sones.
Why avoid unvented attic termination with Ortech ODD-70-1?
Under ASHRAE 62.2 best practice, Ortech ODD-70-1 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Ortech ODD-70-1?
Before cutting ceiling drywall or sizing attic transitions for Ortech ODD-70-1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Ortech (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ODD-70-1 / ODD-70-1 | PD ID 3557061 (Qualified 2024-08-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (62.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.4 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Ortech ODD-70-1?
Bathroom ventilation sizing below maps Ortech ODD-70-1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 62 sq ft | 1 CFM/sq ft @ 62.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 55 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 1.6 kWh/yr (~$0.26/yr) | 4.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 39.4 kWh/yr (~$6.30/yr) | 4.5 W x 8,760 hrs / 1,000 |
What peer models sit nearest Ortech ODD-70-1 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Ortech ODD-70-1.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| DewStop - Breeze Easy BES80 | 80 / 84.9 CFM | 0.3 sones (-0.10) | 16.1 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL80 | 80 / 86.6 CFM | 0.4 sones (Same) | 15.7 CFM/W | 4 in. diameter |
| Broan XB80 | 80 / 80 CFM | 0.3 sones (-0.10) | 13.8 CFM/W | 6 in. diameter |
| Broan XB80=XB00HwithXB80F | 80 / 80 CFM | 0.1 sones (-0.30) | 13.8 CFM/W | 6 in. diameter |
| Revent RVS80 | 80 / 88.8 CFM | 0.6 sones (+0.20) | 12.6 CFM/W | 4 in. diameter |
What percentage of room demand does Ortech ODD-70-1 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Ortech ODD-70-1 tested delivery.
Who should not install Ortech ODD-70-1 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Ortech ODD-70-1 for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 62.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around 0.4 sones up to 62 sq ft
- Primary match: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Ortech ODD-70-1?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Ortech ODD-70-1.
Why check Ortech ODD-70-1 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Ortech ODD-70-1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Ortech ODD-70-1 sound output compare to noisy contractor-grade fans?
Rated at 0.4 sones, Ortech ODD-70-1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Ortech ODD-70-1?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Ortech ODD-70-1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODD-70-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Ortech ODD-70-1?
Ortech ODD-70-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Ortech ODD-70-1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODD-70-1's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Ortech ODD-70-1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Ortech ODD-70-1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Ortech ODD-70-1 undersized or poorly matched for a bath renovation?
Skip Ortech ODD-70-1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.