In EPA dataset 8dv7-nngq, Panasonic FV-0511VKSL3K tests at 110 CFM free discharge (111.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 15.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 111 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VKSL3K Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 111.1 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 15.6 CFM/W (#23/1,145)
- Static Retention
- 101.0% @ 0.25"
- Motor Draw
- 7.1 W (2.6 kWh/yr)
- Duct & Tier
- 6 in. diameter · Most Eff.

What does Panasonic FV-0511VKSL3K vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic FV-0511VKSL3K (EPA filing PD #4682917) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 111.1 CFM out of 110 CFM (101.0% retention, 13.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Manufacturer coverage places FV-0511VKSL3K (series: Whisper Green Select) (PD #4682917) among 92 Panasonic entries qualified through 2026-08-05. Lighting kit: Yes. At 15.6 CFM/W (#23 of 1,145, top 2.0% of 1,145 rated models, more efficient than 98.0% of rated models, 10.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.1 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 62.2 kWh/yr (~$9.95/yr) continuously. Closest competing matches include Delta SIG80-110 (110.0 CFM) and Delta SIG80-110D (110.0 CFM).
Why avoid unvented attic termination with Panasonic FV-0511VKSL3K?
Under ASHRAE 62.2 best practice, Panasonic FV-0511VKSL3K needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Panasonic FV-0511VKSL3K?
Before cutting ceiling drywall or sizing attic transitions for Panasonic FV-0511VKSL3K, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FV-0511VKSL3K / Whisper Green Select | PD ID 4682917 (Qualified 2026-08-05) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (111.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Panasonic FV-0511VKSL3K?
Bathroom ventilation sizing below maps Panasonic FV-0511VKSL3K motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 111 sq ft | 1 CFM/sq ft @ 111.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 98 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 61 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.6 kWh/yr (~$0.42/yr) | 7.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 62.2 kWh/yr (~$9.95/yr) | 7.1 W x 8,760 hrs / 1,000 |
What peer models sit nearest Panasonic FV-0511VKSL3K in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Panasonic FV-0511VKSL3K.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta SIG80-110 | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |
| Delta SIG80-110D | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |
| Delta SIG80-110H | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |
| Delta SIG80-110MH | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |
| Broan ZB110HL1 | 110 / 113.2 CFM | Unpublished | 16.2 CFM/W | 6 in. diameter |
What percentage of room demand does Panasonic FV-0511VKSL3K cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Panasonic FV-0511VKSL3K tested delivery.
Where should contractors skip Panasonic FV-0511VKSL3K on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic FV-0511VKSL3K carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 111.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 111 sq ft
- Works well for: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Panasonic FV-0511VKSL3K?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Panasonic FV-0511VKSL3K.
How much power does Panasonic FV-0511VKSL3K consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Panasonic FV-0511VKSL3K draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Panasonic FV-0511VKSL3K pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VKSL3K's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic FV-0511VKSL3K?
Panasonic FV-0511VKSL3K features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic FV-0511VKSL3K's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VKSL3K's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Panasonic FV-0511VKSL3K score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VKSL3K delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Panasonic FV-0511VKSL3K?
Rule out Panasonic FV-0511VKSL3K when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Panasonic FV-0511VKSL3K capacity?
Because static drag at 0.25 in. w.g. lowers Panasonic FV-0511VKSL3K from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Panasonic FV-0511VKSL3K compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Panasonic FV-0511VKSL3K produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)