Skip to main content
Grant Estimator

Panasonic FV-0511VKSL3K Exhaust Fan Specifications

ENERGY STAR PD #4682917 · Bathroom/Utility Room · Qualified 2026-08-05
Verified Specification Summary

In EPA dataset 8dv7-nngq, Panasonic FV-0511VKSL3K tests at 110 CFM free discharge (111.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 15.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 111 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VKSL3K Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 111.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
15.6 CFM/W (#23/1,145)
Static Retention
101.0% @ 0.25"
Motor Draw
7.1 W (2.6 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0511VKSL3K vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VKSL3K (EPA filing PD #4682917) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 111.1 CFM out of 110 CFM (101.0% retention, 13.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places FV-0511VKSL3K (series: Whisper Green Select) (PD #4682917) among 92 Panasonic entries qualified through 2026-08-05. Lighting kit: Yes. At 15.6 CFM/W (#23 of 1,145, top 2.0% of 1,145 rated models, more efficient than 98.0% of rated models, 10.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.1 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 62.2 kWh/yr (~$9.95/yr) continuously. Closest competing matches include Delta SIG80-110 (110.0 CFM) and Delta SIG80-110D (110.0 CFM).

Why avoid unvented attic termination with Panasonic FV-0511VKSL3K?

Under ASHRAE 62.2 best practice, Panasonic FV-0511VKSL3K needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Panasonic FV-0511VKSL3K?

Before cutting ceiling drywall or sizing attic transitions for Panasonic FV-0511VKSL3K, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0511VKSL3K / Whisper Green Select PD ID 4682917 (Qualified 2026-08-05)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (111.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Panasonic FV-0511VKSL3K?

Bathroom ventilation sizing below maps Panasonic FV-0511VKSL3K motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VKSL3K
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 111 sq ft1 CFM/sq ft @ 111.1 CFM
Tall Bath (9-ft Ceiling)Up to 98 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 61 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.6 kWh/yr (~$0.42/yr)7.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.262.2 kWh/yr (~$9.95/yr)7.1 W x 8,760 hrs / 1,000

What peer models sit nearest Panasonic FV-0511VKSL3K in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Panasonic FV-0511VKSL3K.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta SIG80-110 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110D 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110H 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110MH 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Broan ZB110HL1 110 / 113.2 CFM Unpublished 16.2 CFM/W 6 in. diameter

What percentage of room demand does Panasonic FV-0511VKSL3K cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Panasonic FV-0511VKSL3K tested delivery.

Where should contractors skip Panasonic FV-0511VKSL3K on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic FV-0511VKSL3K carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 111.1 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around ENERGY STAR sones up to 111 sq ft
  • Works well for: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Panasonic FV-0511VKSL3K?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Panasonic FV-0511VKSL3K.

How much power does Panasonic FV-0511VKSL3K consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Panasonic FV-0511VKSL3K draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Panasonic FV-0511VKSL3K pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VKSL3K's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0511VKSL3K?

Panasonic FV-0511VKSL3K features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0511VKSL3K's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VKSL3K's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Panasonic FV-0511VKSL3K score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VKSL3K delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Panasonic FV-0511VKSL3K?

Rule out Panasonic FV-0511VKSL3K when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Panasonic FV-0511VKSL3K capacity?

Because static drag at 0.25 in. w.g. lowers Panasonic FV-0511VKSL3K from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Panasonic FV-0511VKSL3K compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Panasonic FV-0511VKSL3K produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories