In EPA dataset 8dv7-nngq, Broan ZB110HL1 tests at 110 CFM free discharge (113.2 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 16.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 113 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan ZB110HL1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 113.2 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 16.2 CFM/W (#12/1,145)
- Static Retention
- 102.9% @ 0.25"
- Motor Draw
- 6.8 W (2.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan ZB110HL1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan ZB110HL1 (EPA filing PD #2312840) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 113.2 CFM out of 110 CFM (102.9% retention, 15.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Broan maintains 207 active ENERGY STAR blowers; ZB110HL1 (series: ULTRA GREEN) (PD #2312840) gained qualification on 2018-03-16. Lighting kit: Yes. At 16.2 CFM/W (#12 of 1,145, top 1.2% of 1,145 rated models, more efficient than 98.8% of rated models, 11.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.8 watts, about 2.5 kWh/yr (~$0.40/yr at $0.16/kWh) for 1 hr/day shower timers or 59.6 kWh/yr (~$9.54/yr) continuously. Closest competing matches include Panasonic FV-0511VK3 (110.0 CFM) and Panasonic FV-0511VKL3 (110.0 CFM).
Why avoid unvented attic termination with Broan ZB110HL1?
Under ASHRAE 62.2 best practice, Broan ZB110HL1 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Broan ZB110HL1?
Before cutting ceiling drywall or sizing attic transitions for Broan ZB110HL1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ZB110HL1 / ULTRA GREEN | PD ID 2312840 (Qualified 2018-03-16) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (113.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Broan ZB110HL1?
Bathroom ventilation sizing below maps Broan ZB110HL1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 113 sq ft | 1 CFM/sq ft @ 113.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 100 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 63 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.5 kWh/yr (~$0.40/yr) | 6.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 59.6 kWh/yr (~$9.54/yr) | 6.8 W x 8,760 hrs / 1,000 |
What peer models sit nearest Broan ZB110HL1 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan ZB110HL1.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic FV-0511VK3 | 110 / 112.9 CFM | Unpublished | 16.7 CFM/W | 6 in. diameter |
| Panasonic FV-0511VKL3 | 110 / 114.4 CFM | Unpublished | 15.7 CFM/W | 6 in. diameter |
| Panasonic FV-0511VKS3 | 110 / 112.9 CFM | Unpublished | 16.7 CFM/W | 6 in. diameter |
| Panasonic FV-0511VKSL3 | 110 / 114.4 CFM | Unpublished | 15.7 CFM/W | 6 in. diameter |
| Panasonic FV-0511VKSL3K | 110 / 111.1 CFM | Unpublished | 15.6 CFM/W | 6 in. diameter |
What percentage of room demand does Broan ZB110HL1 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan ZB110HL1 tested delivery.
When does Broan ZB110HL1 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan ZB110HL1.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 113.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around ENERGY STAR sones up to 113 sq ft
- Target scenario: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Broan ZB110HL1?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan ZB110HL1.
Will Broan ZB110HL1 disturb adjacent bedrooms during night use?
Acoustic measurement places Broan ZB110HL1 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Broan ZB110HL1 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan ZB110HL1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan ZB110HL1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan ZB110HL1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan ZB110HL1?
Broan ZB110HL1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan ZB110HL1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan ZB110HL1's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Broan ZB110HL1 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan ZB110HL1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan ZB110HL1?
Do not force Broan ZB110HL1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan ZB110HL1 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan ZB110HL1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)