Skip to main content
Grant Estimator

Panasonic FV-0511VKSL3 Exhaust Fan Specifications

ENERGY STAR PD #3442045 · Bathroom/Utility Room · Qualified 2024-03-15
Verified Specification Summary

Certified by EPA ENERGY STAR, Panasonic FV-0511VKSL3 delivers 110 CFM free-air (114.4 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 15.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 114 sq ft (8-ft height) or 101 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VKSL3 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 114.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
15.7 CFM/W (#20/1,145)
Static Retention
104.0% @ 0.25"
Motor Draw
7.0 W (2.6 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0511VKSL3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VKSL3 (EPA filing PD #3442045) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114.4 CFM out of 110 CFM (104.0% retention, 16.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Panasonic FV-0511VKSL3 (series: Whisper Green Select) under PD #3442045 (92 models registered, 2024-03-15). Lighting kit: Yes. At 15.7 CFM/W (#20 of 1,145, top 1.9% of 1,145 rated models, more efficient than 98.1% of rated models, 11.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.0 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 61.3 kWh/yr (~$9.81/yr) continuously. Closest competing matches include Delta SIG80-110 (110.0 CFM) and Delta SIG80-110D (110.0 CFM).

Why does rigid 6 in. diameter ducting protect Panasonic FV-0511VKSL3 airflow?

Connecting Panasonic FV-0511VKSL3 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Panasonic FV-0511VKSL3 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic FV-0511VKSL3 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0511VKSL3 / Whisper Green Select PD ID 3442045 (Qualified 2024-03-15)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (114.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Panasonic FV-0511VKSL3?

Calculated coverage metrics translate Panasonic FV-0511VKSL3 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VKSL3
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 114 sq ft1 CFM/sq ft @ 114.4 CFM
Tall Bath (9-ft Ceiling)Up to 101 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 64 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.6 kWh/yr (~$0.42/yr)7.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.261.3 kWh/yr (~$9.81/yr)7.0 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Panasonic FV-0511VKSL3?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta SIG80-110 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110D 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110H 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110MH 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Broan ZB110HL1 110 / 113.2 CFM Unpublished 16.2 CFM/W 6 in. diameter

Does Panasonic FV-0511VKSL3 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic FV-0511VKSL3 percentage capacity without sending data.

When does Panasonic FV-0511VKSL3 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Panasonic FV-0511VKSL3.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 64 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Moisture load fits 114.4 CFM net static output
  • Target scenario: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Panasonic FV-0511VKSL3?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic FV-0511VKSL3.

Will Panasonic FV-0511VKSL3 disturb adjacent bedrooms during night use?

Acoustic measurement places Panasonic FV-0511VKSL3 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Panasonic FV-0511VKSL3 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Panasonic FV-0511VKSL3 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Panasonic FV-0511VKSL3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VKSL3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0511VKSL3?

Panasonic FV-0511VKSL3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0511VKSL3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VKSL3's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Panasonic FV-0511VKSL3 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VKSL3 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Panasonic FV-0511VKSL3?

Do not force Panasonic FV-0511VKSL3 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Panasonic FV-0511VKSL3 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Panasonic FV-0511VKSL3 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories