Skip to main content
Grant Estimator

Broan ZB110ML1 Exhaust Fan Specifications

ENERGY STAR PD #2312845 · Bathroom/Utility Room · Qualified 2018-03-16
Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan ZB110ML1 tests at 110 CFM free discharge (113.2 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 16.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 113 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan ZB110ML1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 113.2 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
16.2 CFM/W (#12/1,145)
Static Retention
102.9% @ 0.25"
Motor Draw
6.8 W (2.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan ZB110ML1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan ZB110ML1 (EPA filing PD #2312845) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 113.2 CFM out of 110 CFM (102.9% retention, 15.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2312845 verifies ZB110ML1 (series: ULTRA GREEN) under Broan (207 listed models, qualified 2018-03-16). Lighting kit: Yes. At 16.2 CFM/W (#12 of 1,145, top 1.2% of 1,145 rated models, more efficient than 98.8% of rated models, 11.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.8 watts, about 2.5 kWh/yr (~$0.40/yr at $0.16/kWh) for 1 hr/day shower timers or 59.6 kWh/yr (~$9.54/yr) continuously. Closest competing matches include Panasonic FV-0511VK3 (110.0 CFM) and Panasonic FV-0511VKL3 (110.0 CFM).

Why avoid unvented attic termination with Broan ZB110ML1?

Under ASHRAE 62.2 best practice, Broan ZB110ML1 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan ZB110ML1?

Before cutting ceiling drywall or sizing attic transitions for Broan ZB110ML1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series ZB110ML1 / ULTRA GREEN PD ID 2312845 (Qualified 2018-03-16)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (113.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Broan ZB110ML1?

Bathroom ventilation sizing below maps Broan ZB110ML1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan ZB110ML1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 113 sq ft1 CFM/sq ft @ 113.2 CFM
Tall Bath (9-ft Ceiling)Up to 100 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 63 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.5 kWh/yr (~$0.40/yr)6.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.259.6 kWh/yr (~$9.54/yr)6.8 W x 8,760 hrs / 1,000

What peer models sit nearest Broan ZB110ML1 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan ZB110ML1.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic FV-0511VK3 110 / 112.9 CFM Unpublished 16.7 CFM/W 6 in. diameter
Panasonic FV-0511VKL3 110 / 114.4 CFM Unpublished 15.7 CFM/W 6 in. diameter
Panasonic FV-0511VKS3 110 / 112.9 CFM Unpublished 16.7 CFM/W 6 in. diameter
Panasonic FV-0511VKSL3 110 / 114.4 CFM Unpublished 15.7 CFM/W 6 in. diameter
Panasonic FV-0511VKSL3K 110 / 111.1 CFM Unpublished 15.6 CFM/W 6 in. diameter

What percentage of room demand does Broan ZB110ML1 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan ZB110ML1 tested delivery.

Who should not install Broan ZB110ML1 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan ZB110ML1 for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 113.2 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around ENERGY STAR sones up to 113 sq ft
  • Primary match: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Broan ZB110ML1?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan ZB110ML1.

How does Broan ZB110ML1 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Broan ZB110ML1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Broan ZB110ML1?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Broan ZB110ML1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan ZB110ML1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan ZB110ML1?

Broan ZB110ML1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan ZB110ML1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan ZB110ML1's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan ZB110ML1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan ZB110ML1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Broan ZB110ML1 undersized or poorly matched for a bath renovation?

Skip Broan ZB110ML1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Broan ZB110ML1 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan ZB110ML1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories