Homeowners specifying Commercial Electric BF1107 gain 110 CFM at 0.1 in. w.g. (88.6 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 4.3 CFM/W efficacy, venting bathrooms up to 88 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BF1107 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 88.6 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 80.5% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Commercial Electric BF1107 vs. 1,145-Model ENERGY STAR Benchmarks show?
Commercial Electric BF1107 (EPA filing PD #3531184) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 88.6 CFM at 0.25 in. w.g. (80.5% retention, 7.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #3531184 verifies BF1107 (series: BF1107) under Commercial Electric (15 listed models, qualified 2024-05-24). Lighting kit: Yes. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Broan 791LEDM (110.0 CFM) and Nutone 791LEDNTM (110.0 CFM).
Which exterior damper path suits Commercial Electric BF1107 best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Commercial Electric BF1107 housings.
Where do Commercial Electric BF1107 acoustic and static metrics stand?
Compare Commercial Electric BF1107 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Commercial Electric (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BF1107 / BF1107 | PD ID 3531184 (Qualified 2024-05-24) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (88.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Commercial Electric BF1107 handle taller ceilings or walk-in tub steam?
Evaluate how Commercial Electric BF1107 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 88 sq ft | 1 CFM/sq ft @ 88.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 78 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 38 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Commercial Electric BF1107?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan 791LEDM | 110 / 93.4 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
| Nutone 791LEDNTM | 110 / 93.4 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
| Broan AER110LTMB | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Broan AER110LTW | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Nutone AER110SLW | 110 / 89.5 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
Is Commercial Electric BF1107 sized right for your shower or tub room?
Check whether Commercial Electric BF1107 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Does Commercial Electric BF1107 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Commercial Electric BF1107 for your remodel.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 38 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Moisture load fits 88.6 CFM net static output
- Best application: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Commercial Electric BF1107?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Commercial Electric BF1107.
Does duct resistance cut Commercial Electric BF1107 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Commercial Electric BF1107 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Commercial Electric BF1107 occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Commercial Electric BF1107 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Commercial Electric BF1107 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Commercial Electric BF1107 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Commercial Electric BF1107 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BF1107's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Commercial Electric BF1107?
Commercial Electric BF1107 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Commercial Electric BF1107's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BF1107's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Commercial Electric BF1107 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Commercial Electric BF1107 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Commercial Electric BF1107 in a bathroom remodel?
Avoid specifying Commercial Electric BF1107 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)