Homeowners specifying Commercial Electric BF1109 gain 110 CFM at 0.1 in. w.g. (93.3 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 4.0 CFM/W efficacy, venting bathrooms up to 93 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BF1109 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 93.3 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 84.8% @ 0.25"
- Motor Draw
- 27.5 W (10.0 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Commercial Electric BF1109 vs. 1,145-Model ENERGY STAR Benchmarks show?
Commercial Electric BF1109 (EPA filing PD #3531185) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 93.3 CFM at 0.25 in. w.g. (84.8% retention, 2.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places BF1109 (series: BF1109) (PD #3531185) among 15 Commercial Electric entries qualified through 2024-05-24. Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.5 watts, about 10.0 kWh/yr (~$1.60/yr at $0.16/kWh) for 1 hr/day shower timers or 240.9 kWh/yr (~$38.54/yr) continuously. Closest competing matches include Nutone AERN110RGBL (110.0 CFM) and Nutone AERN110RGBLC (110.0 CFM).
Which exterior damper path suits Commercial Electric BF1109 best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Commercial Electric BF1109 housings.
Where do Commercial Electric BF1109 acoustic and static metrics stand?
Compare Commercial Electric BF1109 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Commercial Electric (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BF1109 / BF1109 | PD ID 3531185 (Qualified 2024-05-24) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (93.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Commercial Electric BF1109 handle taller ceilings or walk-in tub steam?
Evaluate how Commercial Electric BF1109 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 93 sq ft | 1 CFM/sq ft @ 93.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 82 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 43 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.0 kWh/yr (~$1.60/yr) | 27.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 240.9 kWh/yr (~$38.54/yr) | 27.5 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Commercial Electric BF1109?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nutone AERN110RGBL | 110 / 97.6 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| Nutone AERN110RGBLC | 110 / 97.6 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| Broan AER110RGBL | 110 / 97 CFM | 1.5 sones | 4.1 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-07-plus | 110 / 91.6 CFM | 1.5 sones | 4.1 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-25L-5CCT(BL) | 110 / 91.6 CFM | 1.5 sones | 4.1 CFM/W | 4 in. diameter |
Is Commercial Electric BF1109 sized right for your shower or tub room?
Check whether Commercial Electric BF1109 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
When does Commercial Electric BF1109 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Commercial Electric BF1109.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 43 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 93.3 CFM net static output
- Target scenario: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Commercial Electric BF1109?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Commercial Electric BF1109.
Does running Commercial Electric BF1109 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Commercial Electric BF1109 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Commercial Electric BF1109 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BF1109's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Commercial Electric BF1109?
Commercial Electric BF1109 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Commercial Electric BF1109's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BF1109's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Commercial Electric BF1109 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Commercial Electric BF1109 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Commercial Electric BF1109?
Do not force Commercial Electric BF1109 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Commercial Electric BF1109 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Commercial Electric BF1109 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Commercial Electric BF1109 disturb adjacent bedrooms during night use?
Acoustic measurement places Commercial Electric BF1109 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)