The Commercial Electric BF1110 (BF1110) moves 110 CFM at 0.1 in. w.g. (93.3 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 4.0 CFM/W efficacy, sizing bathrooms up to 93 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BF1110 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 93.3 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 84.8% @ 0.25"
- Motor Draw
- 27.5 W (10.0 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Commercial Electric BF1110 vs. 1,145-Model ENERGY STAR Benchmarks show?
Commercial Electric BF1110 (EPA filing PD #3543367) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 93.3 CFM at 0.25 in. w.g. (84.8% retention, 2.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Commercial Electric registers 15 certified models, with SKU BF1110 (series: BF1110) (PD #3543367) certified since 2024-05-24. Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.5 watts, about 10.0 kWh/yr (~$1.60/yr at $0.16/kWh) for 1 hr/day shower timers or 240.9 kWh/yr (~$38.54/yr) continuously. Closest competing matches include Nutone AERN110RGBL (110.0 CFM) and Nutone AERN110RGBLC (110.0 CFM).
How does duct geometry alter Commercial Electric BF1110 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Commercial Electric BF1110?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Commercial Electric BF1110 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Commercial Electric (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BF1110 / BF1110 | PD ID 3543367 (Qualified 2024-05-24) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (93.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Commercial Electric BF1110 ventilate safely?
Sizing outputs below convert Commercial Electric BF1110 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 93 sq ft | 1 CFM/sq ft @ 93.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 82 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 43 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.0 kWh/yr (~$1.60/yr) | 27.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 240.9 kWh/yr (~$38.54/yr) | 27.5 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Commercial Electric BF1110 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nutone AERN110RGBL | 110 / 97.6 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| Nutone AERN110RGBLC | 110 / 97.6 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| Broan AER110RGBL | 110 / 97 CFM | 1.5 sones | 4.1 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-07-plus | 110 / 91.6 CFM | 1.5 sones | 4.1 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-25L-5CCT(BL) | 110 / 91.6 CFM | 1.5 sones | 4.1 CFM/W | 4 in. diameter |
Will Commercial Electric BF1110 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Commercial Electric BF1110 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does Commercial Electric BF1110 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Commercial Electric BF1110.
Limitations & Who Should Skip
- Steam or walk-in tub room > 43 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 93 sq ft with 8-ft ceilings (82 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Commercial Electric BF1110?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Commercial Electric BF1110.
How much airflow does Commercial Electric BF1110 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Commercial Electric BF1110 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Commercial Electric BF1110 disturb adjacent bedrooms during night use?
Acoustic measurement places Commercial Electric BF1110 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Commercial Electric BF1110 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Commercial Electric BF1110 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Commercial Electric BF1110 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BF1110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Commercial Electric BF1110?
Commercial Electric BF1110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Commercial Electric BF1110's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BF1110's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Commercial Electric BF1110 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Commercial Electric BF1110 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Commercial Electric BF1110?
Do not force Commercial Electric BF1110 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)