Delta 110HLEDNL Exhaust Fan Specifications

ENERGY STAR PD #2294036 · Bathroom/Utility Room · Qualified 2017-03-24
Verified Specification Summary

Rated for 110 CFM open-air (98.1 CFM at 0.25 in. w.g.), Delta 110HLEDNL omits a published 0.1-inch sone rating and delivers 8.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 98 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 110HLEDNL Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 98.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.3 CFM/W (#321/1,145)
Static Retention
89.2% @ 0.25"
Motor Draw
13.3 W (4.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta 110HLEDNL vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta 110HLEDNL (EPA filing PD #2294036) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 98.1 CFM out of 110 CFM (89.2% retention, 1.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta 110HLEDNL (series: BreezSignature) under PD #2294036 (121 models registered, 2017-03-24). Lighting kit: Yes. At 8.3 CFM/W (#321 of 1,145, top 28.7% of 1,145 rated models, more efficient than 71.3% of rated models, 3.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.3 watts, about 4.9 kWh/yr (~$0.78/yr at $0.16/kWh) for 1 hr/day shower timers or 116.5 kWh/yr (~$18.64/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

How do flex elbows choke Delta 110HLEDNL at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Delta 110HLEDNL moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Delta 110HLEDNL meet residential exhaust fan code specs?

Inspect Delta 110HLEDNL mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series 110HLEDNL / BreezSignature PD ID 2294036 (Qualified 2017-03-24)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (98.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Delta 110HLEDNL airflow output?

Annual electricity figures and room square-footage ceilings below reflect Delta 110HLEDNL tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Delta 110HLEDNL
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 98 sq ft1 CFM/sq ft @ 98.1 CFM
Tall Bath (9-ft Ceiling)Up to 87 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 48 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.9 kWh/yr (~$0.78/yr)13.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2116.5 kWh/yr (~$18.64/yr)13.3 W x 8,760 hrs / 1,000

Which competing models share Delta 110HLEDNL airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-CH 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

How much airflow margin does Delta 110HLEDNL give your bath?

Run a quick local room-volume check for Delta 110HLEDNL by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Delta 110HLEDNL on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta 110HLEDNL carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 48 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 98 sq ft with 8-ft ceilings (87 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Delta 110HLEDNL?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta 110HLEDNL.

How does Delta 110HLEDNL score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta 110HLEDNL delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Delta 110HLEDNL?

Rule out Delta 110HLEDNL when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Delta 110HLEDNL capacity?

Because static drag at 0.25 in. w.g. lowers Delta 110HLEDNL from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Delta 110HLEDNL compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Delta 110HLEDNL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Delta 110HLEDNL consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Delta 110HLEDNL draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Delta 110HLEDNL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 110HLEDNL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta 110HLEDNL?

Delta 110HLEDNL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta 110HLEDNL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 110HLEDNL's safe coverage footprint from 50 sq ft to 44 sq ft.