The Panasonic FV-0511VK3 (Whisper Green Select) moves 110 CFM at 0.1 in. w.g. (112.9 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 16.7 CFM/W efficacy, sizing bathrooms up to 112 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VK3 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 112.9 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 16.7 CFM/W (#1/1,145)
- Static Retention
- 102.6% @ 0.25"
- Motor Draw
- 6.6 W (2.4 kWh/yr)
- Duct & Tier
- 6 in. diameter · Most Eff.

What does Panasonic FV-0511VK3 vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic FV-0511VK3 (EPA filing PD #4682895) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.9 CFM out of 110 CFM (102.6% retention, 14.9 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Inside Panasonic's 92-unit lineup, FV-0511VK3 (series: Whisper Green Select) carries PD #4682895 dating to 2026-08-05. Lighting kit: No. At 16.7 CFM/W (#1 of 1,145, top 0.3% of 1,145 rated models, more efficient than 99.7% of rated models, 12.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.6 watts, about 2.4 kWh/yr (~$0.38/yr at $0.16/kWh) for 1 hr/day shower timers or 57.8 kWh/yr (~$9.25/yr) continuously. Closest competing matches include Broan ZB110HL1 (110.0 CFM) and Broan ZB110L1 (110.0 CFM).
How does duct geometry alter Panasonic FV-0511VK3 static pressure?
Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Panasonic FV-0511VK3?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Panasonic FV-0511VK3 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FV-0511VK3 / Whisper Green Select | PD ID 4682895 (Qualified 2026-08-05) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (112.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Panasonic FV-0511VK3 ventilate safely?
Sizing outputs below convert Panasonic FV-0511VK3 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 100 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.4 kWh/yr (~$0.38/yr) | 6.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 57.8 kWh/yr (~$9.25/yr) | 6.6 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Panasonic FV-0511VK3 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan ZB110HL1 | 110 / 113.2 CFM | Unpublished | 16.2 CFM/W | 6 in. diameter |
| Broan ZB110L1 | 110 / 113.2 CFM | Unpublished | 16.2 CFM/W | 6 in. diameter |
| Broan ZB110ML1 | 110 / 113.2 CFM | Unpublished | 16.2 CFM/W | 6 in. diameter |
| Delta SIG80-110 | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |
| Delta SIG80-110D | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |
Will Panasonic FV-0511VK3 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Panasonic FV-0511VK3 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
What plumbing or duct constraints rule out Panasonic FV-0511VK3?
Compare where Panasonic FV-0511VK3 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Steam or walk-in tub room > 62 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 112 sq ft with 8-ft ceilings (100 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 6 in. diameter
What key rules and numbers govern Panasonic FV-0511VK3?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Panasonic FV-0511VK3.
Why might a contractor swap Panasonic FV-0511VK3 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic FV-0511VK3 lacks adequate reserve.
How does Panasonic FV-0511VK3 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic FV-0511VK3 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.
Is Panasonic FV-0511VK3 quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Panasonic FV-0511VK3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Panasonic FV-0511VK3 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Panasonic FV-0511VK3 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VK3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic FV-0511VK3?
Panasonic FV-0511VK3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic FV-0511VK3's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VK3's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Panasonic FV-0511VK3 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Panasonic FV-0511VK3 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)