Skip to main content
Grant Estimator

Panasonic FV-0511VFL1K Exhaust Fan Specifications

ENERGY STAR PD #2382169 · Bathroom/Utility Room · Qualified 2021-06-04
Verified Specification Summary

The Panasonic FV-0511VFL1K (WhisperFit DC) moves 110 CFM at 0.1 in. w.g. (112.2 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 10.7 CFM/W efficacy, sizing bathrooms up to 112 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VFL1K Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 112.2 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
10.7 CFM/W (#144/1,145)
Static Retention
102.0% @ 0.25"
Motor Draw
10.3 W (3.8 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0511VFL1K vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VFL1K (EPA filing PD #2382169) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.2 CFM out of 110 CFM (102.0% retention, 14.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Panasonic FV-0511VFL1K (series: WhisperFit DC) under PD #2382169 (92 models registered, 2021-06-04). Lighting kit: Yes. At 10.7 CFM/W (#144 of 1,145, top 13.2% of 1,145 rated models, more efficient than 86.8% of rated models, 6.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.3 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 90.2 kWh/yr (~$14.43/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

How does duct geometry alter Panasonic FV-0511VFL1K static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Panasonic FV-0511VFL1K?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Panasonic FV-0511VFL1K alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0511VFL1K / WhisperFit DC PD ID 2382169 (Qualified 2021-06-04)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (112.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Panasonic FV-0511VFL1K ventilate safely?

Sizing outputs below convert Panasonic FV-0511VFL1K tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VFL1K
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 112 sq ft1 CFM/sq ft @ 112.2 CFM
Tall Bath (9-ft Ceiling)Up to 99 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 62 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.8 kWh/yr (~$0.61/yr)10.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.290.2 kWh/yr (~$14.43/yr)10.3 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Panasonic FV-0511VFL1K closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter

Will Panasonic FV-0511VFL1K clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Panasonic FV-0511VFL1K satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Which bath layouts should avoid specifying Panasonic FV-0511VFL1K?

Match Panasonic FV-0511VFL1K directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 62 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 112 sq ft with 8-ft ceilings (99 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Panasonic FV-0511VFL1K?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Panasonic FV-0511VFL1K.

Where does Panasonic FV-0511VFL1K run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Panasonic FV-0511VFL1K.

What happens to Panasonic FV-0511VFL1K CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Panasonic FV-0511VFL1K moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Panasonic FV-0511VFL1K sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Panasonic FV-0511VFL1K produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Panasonic FV-0511VFL1K cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Panasonic FV-0511VFL1K 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Panasonic FV-0511VFL1K pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VFL1K's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0511VFL1K?

Panasonic FV-0511VFL1K features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0511VFL1K's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VFL1K's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Panasonic FV-0511VFL1K ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VFL1K covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories