Panasonic FV-0511VKL3 Exhaust Fan Specifications

ENERGY STAR PD #3442063 · Bathroom/Utility Room · Qualified 2024-03-15
Verified Specification Summary

Tested under HVI protocols, the Panasonic FV-0511VKL3 exhaust unit achieves 110 CFM at 0.1 in. w.g. (114.4 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 15.7 CFM/W efficacy, covering standard baths up to 114 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VKL3 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 114.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
15.7 CFM/W (#20/1,145)
Static Retention
104.0% @ 0.25"
Motor Draw
7.0 W (2.6 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0511VKL3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VKL3 (EPA filing PD #3442063) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114.4 CFM out of 110 CFM (104.0% retention, 16.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #3442063 verifies FV-0511VKL3 (series: Whisper Green Select) under Panasonic (92 listed models, qualified 2024-03-15). Lighting kit: Yes. At 15.7 CFM/W (#20 of 1,145, top 1.9% of 1,145 rated models, more efficient than 98.1% of rated models, 11.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.0 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 61.3 kWh/yr (~$9.81/yr) continuously. Closest competing matches include Delta SIG80-110 (110.0 CFM) and Delta SIG80-110D (110.0 CFM).

What attic duct routing preserves Panasonic FV-0511VKL3 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Panasonic FV-0511VKL3, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Panasonic FV-0511VKL3 measure up on airflow and noise ratings?

Each row below breaks down Panasonic FV-0511VKL3 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0511VKL3 / Whisper Green Select PD ID 3442063 (Qualified 2024-03-15)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (114.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Panasonic FV-0511VKL3 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VKL3
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 114 sq ft1 CFM/sq ft @ 114.4 CFM
Tall Bath (9-ft Ceiling)Up to 101 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 64 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.6 kWh/yr (~$0.42/yr)7.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.261.3 kWh/yr (~$9.81/yr)7.0 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Panasonic FV-0511VKL3?

Compare Panasonic FV-0511VKL3 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta SIG80-110 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110D 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110H 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110MH 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Broan ZB110HL1 110 / 113.2 CFM Unpublished 16.2 CFM/W 6 in. diameter

Can you size Panasonic FV-0511VKL3 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Panasonic FV-0511VKL3 verified capacity.

What plumbing or duct constraints rule out Panasonic FV-0511VKL3?

Compare where Panasonic FV-0511VKL3 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 114.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around ENERGY STAR sones up to 114 sq ft
  • Suited to: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Panasonic FV-0511VKL3?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Panasonic FV-0511VKL3.

Is Panasonic FV-0511VKL3 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Panasonic FV-0511VKL3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VKL3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0511VKL3?

Panasonic FV-0511VKL3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0511VKL3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VKL3's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Panasonic FV-0511VKL3 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Panasonic FV-0511VKL3 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Panasonic FV-0511VKL3 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic FV-0511VKL3 lacks adequate reserve.

How does Panasonic FV-0511VKL3 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic FV-0511VKL3 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is Panasonic FV-0511VKL3 quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Panasonic FV-0511VKL3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories