Tested under HVI protocols, the Panasonic FV-0511VKL3 exhaust unit achieves 110 CFM at 0.1 in. w.g. (114.4 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 15.7 CFM/W efficacy, covering standard baths up to 114 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VKL3 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 114.4 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 15.7 CFM/W (#20/1,145)
- Static Retention
- 104.0% @ 0.25"
- Motor Draw
- 7.0 W (2.6 kWh/yr)
- Duct & Tier
- 6 in. diameter · Most Eff.

What does Panasonic FV-0511VKL3 vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic FV-0511VKL3 (EPA filing PD #3442063) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114.4 CFM out of 110 CFM (104.0% retention, 16.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #3442063 verifies FV-0511VKL3 (series: Whisper Green Select) under Panasonic (92 listed models, qualified 2024-03-15). Lighting kit: Yes. At 15.7 CFM/W (#20 of 1,145, top 1.9% of 1,145 rated models, more efficient than 98.1% of rated models, 11.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.0 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 61.3 kWh/yr (~$9.81/yr) continuously. Closest competing matches include Delta SIG80-110 (110.0 CFM) and Delta SIG80-110D (110.0 CFM).
What attic duct routing preserves Panasonic FV-0511VKL3 CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Panasonic FV-0511VKL3, preventing premature peeling paint and mold growth.
How does Panasonic FV-0511VKL3 measure up on airflow and noise ratings?
Each row below breaks down Panasonic FV-0511VKL3 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FV-0511VKL3 / Whisper Green Select | PD ID 3442063 (Qualified 2024-03-15) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (114.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Panasonic FV-0511VKL3 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 114 sq ft | 1 CFM/sq ft @ 114.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 101 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 64 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.6 kWh/yr (~$0.42/yr) | 7.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 61.3 kWh/yr (~$9.81/yr) | 7.0 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Panasonic FV-0511VKL3?
Compare Panasonic FV-0511VKL3 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta SIG80-110 | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |
| Delta SIG80-110D | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |
| Delta SIG80-110H | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |
| Delta SIG80-110MH | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |
| Broan ZB110HL1 | 110 / 113.2 CFM | Unpublished | 16.2 CFM/W | 6 in. diameter |
Can you size Panasonic FV-0511VKL3 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Panasonic FV-0511VKL3 verified capacity.
What plumbing or duct constraints rule out Panasonic FV-0511VKL3?
Compare where Panasonic FV-0511VKL3 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 114.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around ENERGY STAR sones up to 114 sq ft
- Suited to: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Panasonic FV-0511VKL3?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Panasonic FV-0511VKL3.
Is Panasonic FV-0511VKL3 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Panasonic FV-0511VKL3 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VKL3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic FV-0511VKL3?
Panasonic FV-0511VKL3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic FV-0511VKL3's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VKL3's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Panasonic FV-0511VKL3 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Panasonic FV-0511VKL3 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Panasonic FV-0511VKL3 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic FV-0511VKL3 lacks adequate reserve.
How does Panasonic FV-0511VKL3 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic FV-0511VKL3 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.
Is Panasonic FV-0511VKL3 quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Panasonic FV-0511VKL3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)